English
Language : 

ICS9ERS3125 Datasheet, PDF (14/22 Pages) Integrated Device Technology – Embedded 56-pin Industrial Temperature Range CK505 Compatible Clock
ICS9ERS3125
Embedded 56-Pin Industrial Temperature Range CK505 Compatible Clock
Datasheet
General SMBus serial interface information for the ICS9ERS3125
How to Write:
• Controller (host) sends a start bit.
• Controller (host) sends the write address D2 (H)
• ICS clock will acknowledge
• Controller (host) sends the beginning byte location = N
• ICS clock will acknowledge
• Controller (host) sends the data byte count = X
• ICS clock will acknowledge
• Controller (host) starts sending Byte N through
Byte N + X -1
• ICS clock will acknowledge each byte one at a time
• Controller (host) sends a Stop bit
How to Read:
• Controller (host) will send start bit.
• Controller (host) sends the write address D2 (H)
• ICS clock will acknowledge
• Controller (host) sends the begining byte
location = N
• ICS clock will acknowledge
• Controller (host) will send a separate start bit.
• Controller (host) sends the read address D3 (H)
• ICS clock will acknowledge
• ICS clock will send the data byte count = X
• ICS clock sends Byte N + X -1
• ICS clock sends Byte 0 through byte X (if X(H)
was written to byte 8).
• Controller (host) will need to acknowledge each byte
• Controller (host) will send a not acknowledge bit
• Controller (host) will send a stop bit
Index Block Write Operation
Controller (Host)
ICS (Slave/Receiver)
T
starT bit
Slave Address D2(H)
WR
WRite
ACK
Beginning Byte = N
ACK
Data Byte Count = X
ACK
Beginning Byte N
ACK
Byte N + X - 1
P
stoP bit
ACK
Index Block Read Operation
Controller (Host)
ICS (Slave/Receiver)
T
starT bit
Slave Address D2(H)
WR
WRite
ACK
Beginning Byte = N
ACK
RT
Repeat starT
Slave Address D3(H)
RD
ReaD
ACK
ACK
ACK
Data Byte Count = X
Beginning Byte N
N
Not acknowledge
P
stoP bit
Byte N + X - 1
IDTTM/ICSTM Embedded 56-Pin Industrial Temperature Range CK505 Compatible Clock
14
1612—08/19/09