ELECTRICAL CHARACTERISTICS
Operating conditions: VDD = 4.3...5.5 V, Tj = -40...125 °C, IBN calibrated to 200 µA, reference point GNDS, unless otherwise stated.
Item Symbol Parameter
No.
Conditions
Unit
Min. Typ. Max.
Signal Level Controller ACO
601 Vs()hi
Saturation Voltage hi
at ACO vs. VDD
Vs() = VDD - V();
ADJ(8:0) = 0x11F, I() = -5 mA
ADJ(8:0) = 0x13F, I() = -10 mA
ADJ(8:0) = 0x15F, I() = -25 mA
ADJ(8:0) = 0x17F, I() = -50 mA
1
V
1
V
1
V
1
V
602 Isc()hi
Short-circuit Current hi in ACO
V() = 0 ... VDD - 1 V;
ADJ(8:0) = 0x11F
ADJ(8:0) = 0x13F
ADJ(8:0) = 0x15F
ADJ(8:0) = 0x17F
-10
-20
-50
-100
-5
mA
-10 mA
-25 mA
-50 mA
603 tr()
Current Rise Time in ACO
I(ACO): 0 → 90 % setpoint
1
ms
604 tset()
Current Settling Time in ACO
Square control active, I(ACO): 50 → 100 %
setpoint
400
µs
605 It()min
Control Range Monitoring 1:
lower limit
referenced to range ADJ(6:5)
3
%Isc
606 It()max
Control Range Monitoring 2:
upper limit
referenced to range ADJ(6:5)
90
%Isc
607 Vt()min
Signal Level Monitoring 1:
lower limit
referenced to Vscq()
40
%Vpp
608 Vt()max Signal Level Monitoring 2:
upper limit
referenced to Vscq()
130
%Vpp
Test Current ERR
701 I(ERR) Permissible Test Current
test mode activated
0
1
mA
Bias Current Source and Reference Voltages
801 IBN()
Bias Current Source
MODE(3:0) = 0x01, I(NC) vs. VDDS
180 200 220 µA
802 VPAH
Reference Voltage VPAH
referenced to GND
45
50
55 %VDD
803 V05
Reference Voltage V05
450 500 550 mV
804 V025
Reference Voltage V025
50
%V05
Power-Down-Reset
901 VDDon
Turn-on Threshold
(power-on release)
increasing voltage at VDD vs. GND
3.7
4
4.3
V
902 VDDoff
Turn-off Threshold
(power-down reset)
decreasing voltage at VDD vs. GND
3.2 3.5 3.8
V
903 VDDhys Threshold Hysteresis
VDDhys = VDDon − VDDoff
0.3
V
Clock Oscillator
A01 fclk()
Internal Clock Frequency
MODE(3:0) = 0x0A, fclk(NS)
120 160 200 kHz
Error Signal Input/Output, Pin ERR
B01 Vs()lo
Saturation Voltage lo
vs. GND, I() = 4 mA
0.4
V
B02 Isc()
Short-circuit Current lo
vs. GND; V(ERR) ≤ VDD
V(ERR) > VTMon
4
mA
2
mA
B03 Vt()hi
Input Threshold Voltage hi
vs. GND
2
V
B04 Vt()lo
Input Threshold Voltage lo
vs. GND
0.8
V
B05 Vt()hys Input Hysteresis
Vt()hys = Vt()hi − Vt()lo
300 500
mV
B06 Ipu()
Input Pull-up Current
V() = 0...VDD − 1 V, EPU = 1
-400 -300 -200 µA
B07 Rpu()
Input Pull-Up Resistor
EPU = 0
500
kΩ
B08 Vpu()
Pull-up Voltage
Vpu() = VDD - V(), I() = -5 µA, EPU = 1
0.4
V
B09 VTMon Test Mode Activation Threshold increasing voltage at ERR
VDD + V
1.5
B10 VTMoff Test Mode Disabling Threshold decreasing voltage at ERR
VDD +
V
0.5
B11 VTMhys Test Mode Hysteresis
VTMhys = VTMon − VTMoff
0.15 0.3
V
B12 Ilk()
Leakage Current
tristate or reversed supply voltage
-1
-10 -50
µA