English
Language : 

IC-MSB Datasheet, PDF (16/29 Pages) IC-Haus GmbH – SIN/COS SIGNAL CONDITIONER WITH 1Vpp DRIVER
iC-MSBSAFETY, iC-MSB2
SIN/COS SIGNAL CONDITIONER WITH 1Vpp DRIVER
OPERATING MODES
Rev D2, Page 16/29
In order to calibrate iC-MSB, compensate for the input
signals and test iC-MSB the mode of operation must
be changed. The output function changes according
to the various operating modes; the line drivers and
protection against reverse polarity facility are only ac-
tive in normal mode.
MODE(3:0)
BYP
Code
0x00
0x01
0x02
0x03
0x04
0x05
0x06
0x07
0x08
0x09
0x0A
0x0B
0x0C
0x0D
0x0E
0x0F
Operating Mode
Normal operation
Calibration 1
Calibration 2
iC-Haus Test 1
iC-Haus Test 2
iC-Haus Test 3
iC-Haus Test 4, BYP = 0
iC-Haus Test 4, BYP = 1
Calibration 3
Saturation low
—
iC-Haus Test 5
—
—
—
IDDQ-Test
—
Addr. 0x02; bit 3:0
Addr. 0x0D; bit 5
Pin PS
Pin NS
Pin PC
Pin NC
Pin PZ
Pin NZ
PS
NS
PC
NC
PZ
NZ
TANA0(2) VREFI0
VREFI12 IBN
PZI
NZI
PCH1
NCH1
PCH2
NCH2
VDC1
VDC2
VPAH
VPD
—
CGUCK IPF
V05
PS_out
NS_out
PC_out
NC_out
PZ_out
NZ_out
PS_out
NS_out
PC_out
NC_out
PZ_out
NZ_out
TANA12(0) TANA12(1) TANA12(2) TANA12(3) TANA12(4) TANA12(5)
X4
X6
X3
X5
X1
X2
VTs
VTth
—
—
—
—
SCL, SDA and ERR low
—
—
—
—
—
—
TP
CLK6
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
All PU/PD resistors, oscillator and supply voltage deactivated
—
—
—
—
—
—
Pin ERR
ERR
ERR
—
IERR
IERR
ERR
IERR
ERR
—
—
—
—
—
—
Table 13: Selection of Operating Modes
Calibration Op. Modes
In Calibration Mode 1 the user can measure the BIAS
current (IBN), input amplifier reference potential VREFI
and the analog signals from channel 0 following signal
conditioning (PCH0 and NCH0).
In Calibration Mode 2 the conditioned signals from
channels 1 and 2 are output (PCH1, NCH1, PCH2
and NCH2). In addition the intermediate potentials of
the compensating circuits are also available for CH1
(VDC1) and CH2 (VDC2).
In Calibration Mode 3 the internal temperature moni-
toring signals are provided.
Signal Filter
iC-MSB has a noise limiting signal filter to filter the con-
ditioned analog signals. This can be activated using
ENF.
ENF
Code
0
1
Adr 0x0E, bit 7
Function
Noise limiter deactivated
Noise limiter activated
Table 14: Signal Filtering
Special Device Test Functions
IDDQ-Test, Saturation Low, Saturation High, and Test
1 to 5 are test modes for iC-Haus device tests. With an
activated bypass (BYP = 1), mode iC-Haus Test 4 per-
mits the direct feedthrough of X1 - X6 input signals to
the output pins; in this instance the output impedance
is high-ohmic. Furthermore, if the input voltage divider
is selected (by RINx = 1- -1), it reduces the signal am-
plitudes to approx. 7/8.