English
Language : 

HDMP-3268 Datasheet, PDF (11/18 Pages) Agilent(Hewlett-Packard) – 3.2 Gbit/sec 68x68 Crosspoint Switch
Table 8. HDMP-3268 AC Electrical Specifications
TA = 0°C to TC = +85°C, VCC = VDD = VCC_DOUT = 2.35 V to 2.65 V
Symbol
Parameter
trd, DOUT
DOUT Differential Rise Time
tfd, DOUT
DOUT Differential Fall Time
VIP, DIN
DIN Input Peak-To-Peak Differential Voltage
Units
ps
ps
mV
Min. Typ.
150
150
200
Max.
1600
VOP, DOUT01[1]
DOUT Output Pk-Pk Diff. Voltage at minimum amplitude setting
(Amplitude code=01) with 100 Ohm differential termination
VOP, DOUT10[1]
DOUT Output Pk-Pk Diff. Voltage at mid-range amplitude setting
(Amplitude code=10) with 100 Ohm differential termination
VOP, DOUT11[1]
DOUT Output Pk-Pk Diff. Voltage at maximum amplitude setting
(Amplitude code=11) with 100 Ohm differential termination
tProp
Propagation Delay Time (Delay for data to travel from
High-speed input to High-speed output)
tskew part
Skew between DOUT channels on a single crosspoint part
RJ (Single)[3]
Random Jitter at DOUT[0:67], the High Speed Electrical Data
Port, specified as one sigma deviation of the 50% crossing
point (RMS). Differential output measurement. Single channel
input to single channel output.
DJ (Single)[3]
Deterministic Jitter at DOUT[0:67], the High Speed Electrical
Data Port (pk-pk). Differential output measurement
Single channel input to single channel output.
TJ (Single)[3]
Total jitter for 1E-12 BER (DJ + 14RJ). Differential output
measurement. Single channel input to single channel output.
RJ (Broadcast)[3]
Random Jitter at DOUT[0:67], the High Speed Electrical
Data Port, specified as one sigma deviation of the 50%
crossing point (RMS). Differential output measurement.
Single channel input to all channels output.
DJ (Broadcast)[3] Deterministic Jitter at DOUT[0:67], the High Speed
Electrical Data Port (pk-pk). Differential output measurement.
Single channel input to all channels output.
TJ (Broadcast)[3] Total jitter for 1E-12 BER (DJ + 14RJ). Differential output
measurement. Single channel input to all channels output.
Drate
Guaranteed Operating Rate
mV
550
mV
800
mV
1050
ns
0.25
0.95
ps
350
ps
2
ps
30
ps
58
ps
2.5
ps
40
ps
75
Gbit/sec Note 2
3.2
Notes:
1. Output Peak-to-Peak Differential Voltage specified as DOUT+ minus DOUT-. This measurement is made using a repeating 1010 pattern. Vop
amplitude can be adjusted with the program register.
2. Minimum data rate depends on the value of AC input coupling capacitance and input resistance which is 100 Ohms between the positive and
negative inputs.
3. Jitter measurement was carried out using a 3.3G BERT with a base jitter of 19ps for Deterministic Jitter and 0.97ps for Random Jitter. For eye
diagrams, please see application notes. Jitter Measurement is taken using a K28.5 pattern at 3.2Gbaud data rate.
11