Item
Symbol Min
Typ Max
Measurement
Unit Condition
Notes
Power
IEE
consumption
—
—
20
µA
Master mode
1/240 duty cycle,
7, 11
Cf = 100 pF,
Rf = 180 kΩ
VCC–GND = 3V
VCC–VEE = 28V,
Notes: 1. Applies to input pins MEOR, MWS0 to MWS5, DUTY, SHL, ',632)), M/6, 5(6(7, and CR,
and when inputting to input/output pins CL1, FLM, '2&, and M.
2. Applies when outputting from input/output pins CL1, FLM, '2&, and M.
3. Applies to V1L/R, V2L/R, V5L/R, and V6L/R. X1 to X240 are open.
4. Figure 17 shows the external clock specifications:
TH
TL
0.8VCC
0.5VCC
0.2VCC
trcp
tfcp
External
OPEN OPEN
clock
CR R C
Duty = TH × 100%
TH + TL
Min Typ Max Unit
Duty 45 50 55 %
trcp — — 50 ns
tfcp — — 50 ns
Figure 17 External Clock
5. Regulates to operation frequency limits of the bidirectional shift register in the slavemode.
6. Connect resistance Rf and capacitance Cf as follows:
Cf
Rf
CR R C
Figure 18 Timing Components
7. Input and output currents are excluded. When a CMOS input is floating, excess current flows
from the power supply through to the input circuit. To avoid this, VIH and VIL must be held to
VCC and GND levels, respectively.
8. This value is specified for the current flowing through GND under the following conditions:
Internal oscillation circuit is used. Each terminal of MEOR, MWS0 to MWS5, DUTY, SHL,
',632)), M/6, and 5(6(7 is connected to VCC. Oscillator is set as described in note 6.
9. This value is specified for the current flowing through GND under the following conditions: Each
terminal of MEOR, MWS0 to MWS5, DUTY, SHL, ',632)), M/6, and 5(6(7 is connected to
VCC. Oscillator is set as described in note 4.