Low-Voltage Inhibit (LVI)
16.6.2 Stop Mode
With the LVISTOP and LVIPWR bits in the configuration register programmed to a logic 1, the LVI module
will be active after a STOP instruction. Because CPU clocks are disabled during stop mode, the LVI trip
must bypass the digital filter to generate a reset and bring the MCU out of stop.
With the LVIPWR bit in the configuration register programmed to logic 1 and the LVISTOP bit at a logic 0,
the LVI module will be inactive after a STOP instruction.
NOTE
The LVI feature is intended to provide the safe shutdown of the
microcontroller and thus protection of related circuitry prior to any
application VDD voltage collapsing completely to an unsafe level. It is not
intended that users operate the microcontroller at lower than specified
operating voltage VDD.