English
Language : 

XR16L788IQ-F Datasheet, PDF (35/54 Pages) Exar Corporation – HIGH PERFORMANCE 2.97V TO 5.5V OCTAL UART
XR16L788
REV. 1.2.3
HIGH PERFORMANCE 2.97V TO 5.5V OCTAL UART
LCR[7]: Baud Rate Divisors Enable
Baud rate generator divisor (DLL/DLM) enable.
• Logic 0 = Data registers are selected (default).
• Logic 1 = Divisor latch registers are selected.
4.7 Modem Control Register (MCR) - Read/Write
The MCR register is used for controlling the modem interface signals or general purpose inputs/outputs.
MCR[0]: DTR# Output
The DTR# pin may be used for automatic hardware flow control enabled by EFR bit-6 and MCR bit-2=1. If the
modem interface is not used, this output may be used for general purpose.
• Logic 0 = Force DTR# output to a logic 1 (default).
• Logic 1 = Force DTR# output to a logic 0.
MCR[1]: RTS# Output
The RTS# pin may be used for automatic hardware flow control by enabled by EFR bit-6 and MCR bit-2=0. If
the modem interface is not used, this output may be used for general purpose.
• Logic 0 = Force RTS# output to a logic 1 (default).
• Logic 1 = Force RTS# output to a logic 0.
MCR[2]: RTS/CTS or DTR/DSR for Auto Flow Control
DTR# or RTS# auto hardware flow control select. This bit is in effect only when auto RTS/DTR is enabled by
EFR bit-6.
• Logic 0 = RTS# (RX side) and CTS# (TX side) pins are used for auto hardware flow control (default).
• Logic 1 = DTR# (RX side) and DSR# (TX side) pins are used for auto hardware flow control.
MCR[3]: Reserved
MCR[4]: Internal Loopback Enable
• Logic 0 = Disable loopback mode (default).
• Logic 1 = Enable local loopback mode, see loopback section and Figure 12.
MCR[5]: Xon-Any Enable
• Logic 0 = Disable Xon-Any function (default).
• Logic 1 = Enable Xon-Any function. In this mode any RX character received will enable Xon, resume data
transmission.
MCR[6]: Infrared Encoder/Decoder Enable
The state of this bit depends on the sampled logic level of pin ENIR during power up, following a hardware
reset (rising edge of RST# input). Afterward user can override this bit for desired operation.
• Logic 0 = Enable the standard modem receive and transmit character interface.
• Logic 1 = Enable infrared IrDA receive and transmit inputs/outputs. While in this mode, the TX/RX output/
input are routed to the infrared encoder/decoder. The data input and output levels will conform to the IrDA
infrared interface requirement. As such, while in this mode the infrared TX output will be a logic 0 during idle
data conditions. FCTR bit-4 may be selected to invert the RX input signal level going to the decoder for
infrared modules that provide rather an inverted output.
MCR[7]: Clock Prescaler Select
• Logic 0 = Divide by one. The input clock from the crystal or external clock is fed directly to the Programmable
Baud Rate Generator without further modification, i.e., divide by one (default).
• Logic 1 = Divide by four. The prescaler divides the input clock from the crystal or external clock by four and
feeds it to the Programmable Baud Rate Generator, hence, data rates become one forth.
35