English
Language : 

BXRC-17E10K0-B-74-SE Datasheet, PDF (9/32 Pages) List of Unclassifed Manufacturers – Bridgelux Vero SE 29 Array Series
Product Selection Guide
Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued)
Part Number
Nominal
CCT1 (K)
CRI2
Nominal Drive
Current3
(mA)
Typical DC
Flux4,5
Tc = 85ºC
(lm)
Minimum DC
Flux6
Tc = 85ºC
(lm)
BXRC-40E10K0-B-7x-SE
4000
80
BXRC-40E10K0-C-7x-SE
4000
80
BXRC-40E10K0-D-7x-SE
4000
80
BXRC-40G10K0-B-7x-SE
4000
90
BXRC-40G10K0-C-7x-SE
4000
90
BXRC-40G10K0-D-7x-SE
4000
90
BXRC-40A10K1-B-73-SE7,8
4000
93
BXRC-40A10K1-C-73-SE7,8
4000
93
BXRC-40A10K1-D-73-SE7,8
4000
93
BXRC-50C10K1-B-7x-SE
5000
70
BXRC-50C10K1-C-7x-SE
5000
70
BXRC-50C10K1-D-7x-SE
5000
70
BXRC-50E10K1-B-7x-SE
5000
80
BXRC-50E10K1-C-7x-SE
5000
80
BXRC-50E10K1-D-7x-SE
5000
80
BXRC-50G10K1-B-7x-SE
5000
90
BXRC-50G10K1-C-7x-SE
5000
90
BXRC-50G10K1-D-7x-SE
5000
90
BXRC-56G10K0-B-74-SE
5600
90
BXRC-56G10K0-C-74-SE
5600
90
BXRC-56G10Kx-D-74-SE
5600
90
BXRC-56H10K0-D-74-SE
5600
97
BXRC-57C10K1-B-7x-SE
5700
70
BXRC-57C10K1-C-7x-SE
5700
70
BXRC-57C10K1-D-7x-SE
5700
70
BXRC-57E10K1-B-7x-SE
5700
80
BXRC-57E10K1-C-7x-SE
5700
80
BXRC-57E10K1-D-7x-SE
5700
80
BXRC-65C10K1-B-7x-SE
6500
70
BXRC-65C10K1-C-7x-SE
6500
70
BXRC-65C10K1-D-7x-SE
6500
70
BXRC-65E10K1-B-7x-SE
6500
80
BXRC-65E10K1-C-7x-SE
6500
80
BXRC-65E10K1-D-7x-SE
6500
80
1800
1710
2100
1800
1710
2100
1800
1710
2100
1800
1710
2100
1800
1710
2100
1800
1710
2100
1800
1710
2100
2100
1800
1710
2100
1800
1710
2100
1800
1710
2100
1800
1710
2100
13551
17165
11418
11597
14689
9771
11601
14694
9775
14854
18815
12516
13963
17686
11765
11883
15052
10013
12442
15759
10483
9574
14333
18155
12077
14203
17990
11967
14594
18485
12297
14463
18320
12187
12196
15448
10277
10437
13220
8794
10441
13225
8797
13369
16934
11264
12567
15918
10589
10695
13547
9012
11198
14184
9434
8617
12900
16340
10869
12782
16191
10770
13134
16637
11067
13017
16488
10968
Typical Vf
(V)
50.7
68.1
36.6
50.7
68.1
36.6
50.7
68.1
36.6
50.7
68.1
36.6
50.7
68.1
36.6
50.7
68.1
36.6
50.7
68.1
36.6
36.6
50.7
68.1
36.6
50.7
68.1
36.6
50.7
68.1
36.6
50.7
68.1
36.6
Typical
Power
(W)
91.2
116.4
76.8
91.2
116.4
76.8
91.2
116.4
76.8
91.2
116.4
76.8
91.2
116.4
76.8
91.2
116.4
76.8
91.2
116.4
76.8
76.8
91.2
116.4
76.8
91.2
116.4
76.8
91.2
116.4
76.8
91.2
116.4
76.8
Typical
Efficacy
(lm/W)
149
147
149
127
126
127
127
126
127
163
162
163
153
152
153
130
129
130
136
135
137
125
157
156
157
156
155
156
160
159
160
159
157
159
Notes for Table 3:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2.
All
for
CalRl Iovthaelurepsroadreucmtse.aMsuinriemduamt TRj 9=
Tvac l=u2e5f°oCr.
CRI values are typical for
80 CRI products is 0, the
Decor Series
minimum R9
Ultra and
values for
Decor Series Class
90 CRI products is
A products. CRI values are minimums
50, the minimum R9 values for 97 CRI
products is 93. Bridgelux maintains a ± 3 tolerance on R9 values.
3. Drive current is referred to as nominal drive current.
4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface
material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux
test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may
vary depending on fixture design and performance.
7