Performance Curves
Figure 17: Vero SE 29D Drive Current Derating Curve
4400
4200
4000
3960
3800
3600
3400
3200
0
Max Drive Current
LM-80 Max Drive Current
10
20
30
40
50
60
70
80
90 100 110
Case Temperature (⁰C)
Notes for Figure 17:
1. The maximum allowable drive current for the Vero 29D product is dependent on the operating case temperature. Please refer to the Product
Feature Map (page 2) for the location of the Tc Point
2. LM-80 Max Drive Current must not be exceeded in order to meet LM-80 lifetime projections.
3. Lumen maintenance (L70) and lifetime predictions are valid for drive current and case temperature conditions used for LM-80 testing as included
in the applicable LM-80 test report for these products. Contact your Bridgelux sales representative for LM-80 report.