BXRC-17E10K0-B-74-SE Datasheet, PDF (8/32 Pages) List of Unclassifed Manufacturers – Bridgelux Vero SE 29 Array Series
Product Selection Guide
Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5
Part Number
Nominal
CCT1 (K)
CRI2
Nominal Drive
Current3
(mA)
Typical DC
Flux4,5
Tc = 85ºC
(lm)
BXRC-17E10K0-B-74-SE
1750
80
BXRC-17E10K0-C-74-SE
1750
80
BXRC-17E10K0-D-74-SE
1750
80
BXRC-20B10K1-C-73-SE
2000
65
BXRC-20B10K1-D-73-SE
2000
65
BXRC-25E10K0-B-74-SE
2500
80
BXRC-25E10K0-C-74-SE
2500
80
BXRC-25E10K0-D-74-SE
2500
80
BXRC-27E10K0-B-7x-SE
2700
80
BXRC-27E10K0-C-7x-SE
2700
80
BXRC-27E10K0-D-7x-SE
2700
80
BXRC-27G10K0-B-7x-SE
2700
90
BXRC-27G10K0-C-7x-SE
2700
90
BXRC-27G10K0-D-7x-SE
2700
90
BXRC-27H10K0-D-74-SE
2700
97
BXRC-30E10K0-B-7x-SE
3000
80
BXRC-30E10K0-C-7x-SE
3000
80
BXRC-30E10K0-D-7x-SE
3000
80
BXRC-30G10K0-B-7x-SE
3000
90
BXRC-30G10K0-C-7x-SE
3000
90
BXRC-30G10K0-D-7x-SE
3000
90
BXRC-30H10K0-D-7X-SE
3000
97
BXRC-30A10K1-B-73-SE7,8
3000
93
BXRC-30A10K1-C-73-SE7,8
3000
93
BXRC-30A10K1-D-73-SE7,8
3000
93
BXRC-35E10K0-B-7x-SE
3500
80
BXRC-35E10K0-C-7x-SE
3500
80
BXRC-35E10K0-D-7x-SE
3500
80
BXRC-35G10K0-B-7x-SE
3500
90
BXRC-35G10K0-C-7x-SE
3500
90
BXRC-35G10K0-D-7x-SE
3500
90
BXRC-35A10K1-B-73-SE7,8
3500
93
BXRC-35A10K1-C-73-SE7,8
3500
93
BXRC-35A10K1-D-73-SE7,8
3500
93
1800
1710
2100
1710
2100
1800
1710
2100
1800
1710
2100
1800
1710
2100
2100
1800
1710
2100
1800
1710
2100
2100
1800
1710
2100
1800
1710
2100
1800
1710
2100
1800
1710
2100
7230
9157
6091
15440
10270
11685
14801
9846
12509
15845
10540
10424
13204
8783
7659
13030
16505
11309
10815
13699
9113
8156
10088
12778
8500
13421
17000
11308
11206
14194
9442
10845
13736
9137
Minimum DC
Flux6
Tc = 85ºC
(lm)
6507
8241
5483
13896
9243
10516
13321
8861
11258
14260
9486
9381
11884
7905
6893
11727
14854
9882
9733
12329
8201
7340
9079
11500
7650
12079
15299
10178
10085
12775
8498
9760
12363
8223
Typical Vf
(V)
50.7
68.1
36.6
68.1
36.6
50.7
68.1
36.6
50.7
68.1
36.6
50.7
68.1
36.6
7404
50.7
68.1
36.6
50.7
68.1
36.6
36.6
50.7
68.1
36.6
50.7
68.1
36.6
50.7
68.1
36.6
50.7
68.1
36.6
Typical
Power
(W)
91.2
116.4
76.8
116.4
76.8
91.2
116.4
76.8
91.2
116.4
76.8
91.2
116.4
76.8
76.8
91.2
116.4
76.8
91.2
116.4
76.8
76.8
91.2
116.4
76.8
91.2
116.4
76.8
91.2
116.4
76.8
91.2
116.4
76.8
Typical
Efficacy
(lm/W)
79
79
79
133
134
128
127
128
137
136
137
114
113
114
100
143
142
147
119
118
119
106
111
110
111
147
146
147
123
122
123
119
118
119
Notes for Table 3:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. All
for
CRI values are measured at
all other products. Minimum
TRj 9=
vTac l=ue25f°oCr.
CRI values are typical for Decor Series Ultra and
80 CRI products is 0, the minimum R9 values for
Decor Series Class A products. CRI values are minimums
90 CRI products is 50, the minimum R9 values for 97 CRI
products is 93. Bridgelux maintains a ± 3 tolerance on R9 values.
3. Drive current is referred to as nominal drive current.
4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface
material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux
test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may
vary depending on fixture design and performance.
6