Performance at Commonly Used Drive Currents
Vero SE LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. Vero SE may also
be driven at other drive currents dependent on specific application design requirements. The performance at any
drive current can be derived from the current vs. voltage characteristics shown in Figures 1, 2 & 3 and the flux vs. current
characteristics shown in Figures 4, 5 & 6. The performance at commonly used drive currents is summarized in Table 4.
Table 4: Product Performance at Commonly Used Drive Currents
Part Number
CRI
BXRC-17E10K0-B-74-SE 80
BXRC-17E10K0-C-74-SE 80
BXRC-17E10K0-D-74-SE 80
BXRC-20B10K1-C-73-SE 65
BXRC-20B10K1-D-73-SE 65
BXRC-25E10K0-B-74-SE 80
BXRC-25E10K0-C-74-SE 80
BXRC-25E10K0-D-74-SE 80
Drive
Current1
(mA)
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
Typical Vf
Tc = 25ºC
(V)
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
Typical
Power
Tc = 25ºC
(W)
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
Typical
Flux2
Tc = 25ºC
(lm)
4170
5491
8033
11579
14820
5780
7346
10175
14434
18091
3723
4791
6768
9635
12144
9745
12386
17155
24336
30503
6277
8078
11411
16245
20475
6740
8875
12983
18715
23954
9342
11874
16446
23330
29242
6017
7744
10940
15574
19629
Typical
DC Flux3
Tc = 85ºC
(lm)
3807
4991
7230
10327
13058
5500
6776
9157
12414
15202
3627
4459
6091
8119
9917
9273
11425
15440
20931
25631
6116
7518
10270
13688
16719
6152
8067
11685
16691
21105
8890
10953
14801
20066
24572
5863
7207
9846
13123
16029
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Typical
Efficacy
Tc = 25ºC
(lm/W)
93
91
86
79
74
102
96
86
78
71
100
95
86
77
70
172
161
145
132
120
169
160
145
131
118
151
147
139
128
119
165
155
139
126
115
162
153
139
125
113
8