English
Language : 

BXRC-17E10K0-B-74-SE Datasheet, PDF (6/32 Pages) List of Unclassifed Manufacturers – Bridgelux Vero SE 29 Array Series
Product Selection Guide
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued)
Part Number
Nominal
CCT1
(K)
CRI2
BXRC-40E10K0-B-7x-SE10
4000
80
BXRC-40E10K0-C-7x-SE10
4000
80
BXRC-40E10K0-D-7x-SE10
4000
80
BXRC-40G10K0-B-7x-SE
4000
90
BXRC-40G10K0-C-7x-SE
4000
90
BXRC-40G10K0-D-7x-SE
4000
90
BXRC-40A10K1-B-73-SE8,9
4000
93
BXRC-40A10K1-C-73-SE8,9
4000
93
BXRC-40A10K1-D-73-SE8,9
4000
93
BXRC-50C10K1-B-7x-SE10
5000
70
BXRC-50C10K1-C-7x-SE10
5000
70
BXRC-50C10K1-D-7x-SE10
5000
70
BXRC-50E10K1-B-7x-SE10
5000
80
BXRC-50E10K1-C-7x-SE10
5000
80
BXRC-50E10K1-D-7x-SE10
5000
80
BXRC-50G10K1-B-7x-SE
5000
90
BXRC-50G10K1-C-7x-SE
5000
90
BXRC-50G10K1-D-7x-SE
5000
90
BXRC-56G10K0-B-74-SE
5600
90
BXRC-56G10K0-C-74-SE
5600
90
BXRC-56G10Kx-D-74-SE
5600
90
BXRC-56H10K0-D-74-SE
5600
97
BXRC-57C10K1-B-7x-SE10
5700
70
BXRC-57C10K1-C-7x-SE10
5700
70
BXRC-57C10K1-D-7x-SE10
5700
70
BXRC-57E10K1-B-7x-SE10
5700
80
BXRC-57E10K1-C-7x-SE10
5700
80
BXRC-57E10K1-D-7x-SE10
5700
80
BXRC-65C10K1-B-7x-SE10
6500
70
BXRC-65C10K1-C-7x-SE10
6500
70
BXRC-65C10K1-D-7x-SE10
6500
70
BXRC-65E10K1-B-7x-SE10
6500
80
BXRC-65E10K1-C-7x-SE10
6500
80
BXRC-65E10K1-D-7x-SE10
6500
80
Nominal
Drive
Current3
(mA)
1800
1710
2100
1800
1710
2100
1800
1710
2100
1800
1710
2100
1800
1710
2100
1800
1710
2100
1800
1710
2100
2100
1800
1710
2100
1800
1710
2100
1800
1710
2100
1800
1710
2100
Typical Pulsed
Flux4,5,6
Tc = 25ºC
(lm)
15057
19072
12687
12885
16321
10857
12890
16327
10861
16505
20906
13907
15515
19652
13072
13204
16725
11125
13824
17510
11648
10638
15926
20172
13419
15781
19989
13297
16215
20539
13663
16070
20356
13541
Minimum
Pulsed Flux6,7
Tc = 25ºC
(lm)
13551
17165
11418
11597
14689
9772
11601
14694
9775
14855
18816
12516
13963
17687
11766
11883
15052
10013
12442
15760
10483
9574
14333
18155
12077
14202
17990
11967
14593
18486
12296
14464
18320
12186
Typical Vf
(V)
52.0
69.4
37.6
52.0
69.4
37.6
52.0
69.4
37.6
52.0
69.4
37.6
52.0
69.4
37.6
52.0
69.4
37.6
52.0
69.4
37.6
37.6
52.0
69.4
37.6
52.0
69.4
37.6
52.0
69.4
37.6
52.0
69.4
37.6
Typical
Power
(W)
93.6
118.7
79.0
93.6
118.7
79.0
93.6
118.7
79.0
93.6
118.7
79.0
93.6
118.7
79.0
93.6
118.7
79.0
93.6
118.7
79.0
79.0
93.6
118.7
79.0
93.6
118.7
79.0
93.6
118.7
79.0
93.6
118.7
79.0
Typical
Efficacy
(lm/W)
161
161
161
138
138
138
138
138
138
176
176
176
166
166
166
141
141
141
148
148
148
135
170
170
170
169
168
168
173
173
173
172
172
171
Notes for Table 1:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2.
All CRI values are measured
other products. Minimum R9
avtaTluj e=
Tfocr=8205°CCR. CI pRrIovdaulucetss
are
is 0,
typical for Decor
the minimum R9
Series Ultra and Decor Series
values for 90 CRI products is
Class A products. CRI values are minimums for
50, the minimum R9 values for 97 CRI products
all
is
93. Bridgelux maintains a ± 3 tolerance on R9 values.
3. Drive current is referred to as nominal drive current.
4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Minimum flux values at the nominal test current are guaranteed by 100% test.
8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary
depending on fixture design and performance.
10. SKUs meet DLC premium (Outdoor Mid Output) requirements under certain system level conditions.