English
Language : 

BXRC-17E10K0-B-74-SE Datasheet, PDF (5/32 Pages) List of Unclassifed Manufacturers – Bridgelux Vero SE 29 Array Series
Product Selection Guide
The following product configurations are available:
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C)
Part Number
Nominal
CCT1
(K)
CRI2
Nominal
Drive
Current3
(mA)
Typical Pulsed
Flux4,5,6
Tc = 25ºC
(lm)
Minimum
Pulsed Flux6,7
Tc = 25ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-17E10K0-B-74-SE
1750
80
1800
8033
7230
52.0
93.6
86
BXRC-17E10K0-C-74-SE
1750
80
1710
10175
9157
69.4
118.7
86
BXRC-17E10K0-D-74-SE
1750
80
2100
6768
6092
37.6
79.0
86
BXRC-20B10K1-C-73-SE
2000
65
1710
17155
15440
69.4
118.7
145
BXRC-20B10K1-D-73-SE
2000
65
2100
11411
10270
37.6
79.0
145
BXRC-25E10K0-B-74-SE
2500
80
1800
12983
11685
52.0
93.6
139
BXRC-25E10K0-C-74-SE
2500
80
1710
16446
14801
69.4
118.7
139
BXRC-25E10K0-D-74-SE
2500
80
2100
10940
9845
37.6
79.0
139
BXRC-27E10K0-B-7x-SE
2700
80
1800
13899
12509
52.0
93.6
148
BXRC-27E10K0-C-7x-SE
2700
80
1710
17605
15844
69.4
118.7
148
BXRC-27E10K0-D-7x-SE
2700
80
2100
11711
10540
37.6
79.0
148
BXRC-27G10K0-B-7x-SE
2700
90
1800
11582
10424
52.0
93.6
124
BXRC-27G10K0-C-7x-SE
2700
90
1710
14671
13204
69.4
118.7
124
BXRC-27G10K0-D-7x-SE
2700
90
2100
9759
8783
37.6
79.0
124
BXRC-27H10K0-D-74-SE
2700
97
2100
8510
7659
37.6
79.0
108
BXRC-30E10K0-B-7x-SE10
3000
80
1800
14478
13030
52.0
93.6
155
BXRC-30E10K0-C-7x-SE10
3000
80
1710
18339
16505
69.4
118.7
155
BXRC-30E10K0-D-7x-SE10
3000
80
2100
12565
10979
37.6
79.0
159
BXRC-30G10K0-B-7x-SE
3000
90
1800
12017
10815
52.0
93.6
128
BXRC-30G10K0-C-7x-SE
3000
90
1710
15221
13699
69.4
118.7
128
BXRC-30G10K0-D-7x-SE
3000
90
2100
10125
9112
37.6
79.0
128
BXRC-30H10K0-D-7X-SE
3000
97
2100
9062
8156
37.6
79.0
115
BXRC-30A10K1-B-73-SE8,9
3000
93
1800
11209
10088
52.0
93.6
120
BXRC-30A10K1-C-73-SE8,9
3000
93
1710
14197
12778
69.4
118.7
120
BXRC-30A10K1-D-73-SE8,9
3000
93
2100
9444
8500
37.6
79.0
120
BXRC-35E10K0-B-7x-SE10
3500
80
1800
14912
13421
52.0
93.6
159
BXRC-35E10K0-C-7x-SE10
3500
80
1710
18889
16999
69.4
118.7
159
BXRC-35E10K0-D-7x-SE10
3500
80
2100
12565
11309
37.6
79.0
159
BXRC-35G10K0-B-7x-SE
3500
90
BXRC-35G10K0-C-7x-SE
3500
90
BXRC-35G10K0-D-7x-SE
3500
90
BXRC-35A10K1-B-73-SE8,9
3500
93
1800
1710
2100
1800
12451
15771
10491
12050
11206
14194
9442
10845
52.0
93.6
133
69.4
118.7
133
37.6
79.0
133
52.0
93.6
129
BXRC-35A10K1-C-73-SE8,9
3500
93
1710
15263
13737
69.4
118.7
129
BXRC-35A10K1-D-73-SE8,9
3500
93
2100
10153
9137
37.6
79.0
129
Notes for Table 1:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2.
All
for
CalRl Iovthaelurepsroadreucmtse.aMsuinriemduamt TRj 9=
Tvac l=u2e5f°oCr.
CRI values are typical for
80 CRI products is 0, the
Decor Series
minimum R9
Ultra and
values for
Decor Series Class
90 CRI products is
A products. CRI values are minimums
50, the minimum R9 values for 97 CRI
products is 93. Bridgelux maintains a ± 3 tolerance on R9 values.
3. Drive current is referred to as nominal drive current.
4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Minimum flux values at the nominal test current are guaranteed by 100% test.
8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may
vary depending on fixture design and performance.
10. SKUs meet DLC premium (Outdoor Mid Output) requirements under certain system level conditions.
3