English
Language : 

BXRC-17E10K0-B-74-SE Datasheet, PDF (7/32 Pages) List of Unclassifed Manufacturers – Bridgelux Vero SE 29 Array Series
Product Selection Guide
Table 2: Selection Guide, Stabilized DC Performance (Tc = 70°C) 7,8
Part Number
BXRC-30A10K1-B-73-SE
BXRC-30A10K1-C-73-SE
BXRC-30A10K1-D-73-SE
BXRC-35A10K1-B-73-SE
BXRC-35A10K1-C-73-SE
BXRC-35A10K1-D-73-SE
BXRC-40A10K1-B-73-SE
BXRC-40A10K1-C-73-SE
BXRC-40A10K1-D-73-SE
Nominal
CCT1
(K)
3000
3000
3000
3500
3500
3500
4000
4000
4000
GAI2
80
80
80
80
80
80
80
80
80
CRI3
Nominal
Drive
Current4
(mA)
Typical DC
Flux5,6
Tc = 70ºC
(lm)
Minimum DC
Flux6,9
Tc = 70ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
93
1800
10424
9382
50.9
91.6
114
93
1710
13204
11884
67.9
116.1
114
93
2100
8783
7905
36.8
77.3
114
93
1800
11206
10086
50.9
91.6
122
93
1710
14194
12775
67.9
116.1
122
93
2100
9442
8498
36.8
77.3
122
93
1800
11987
10789
50.9
91.6
131
93
1710
15184
13666
67.9
116.1
131
93
2100
10101
9090
36.8
77.3
131
Notes for Table 2:
1. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
2. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on
fixture design and performance.
3. CRI Values are specified as typical.
4. Drive current is referred to as nominal drive current.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
8. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material
and the case temperature maintained at specified temperature. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
9. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test
setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
5