English
Language : 

SI8513-C-IS Datasheet, PDF (7/37 Pages) List of Unclassifed Manufacturers – Si85XX UNIDIRECTIONAL AC CURRENT SENSORS
Si85xx
Table 5. IEC 60747-5-2 Insulation Characteristics*
Parameter
Symbol
Test Condition
Characteristic Unit
SOIC-20
Maximum Working Insulation Voltage
Input to Output Test Voltage
VIORM
VPR
Method b1
(VIORM x 1.875 = VPR, 100%
Production Test, tm = 1 sec,
Partial Discharge < 5 pC)
1414
2652
V peak
V peak
Transient Overvoltage
VIOTM
t = 60 s
8000
V peak
Pollution Degree
(DIN VDE 0110, Table 1)
Insulation Resistance at TS, VIO = 500 V
RS
2
>109
W
Note: The Si85xx is suitable for basic and reinforced electrical isolation only within the safety limit data. Maintenance of the
safety data is ensured by protective circuits. The Si85xx provides a climate classification of 40/125/21. Note that the
Si85xx is compliant with the IEC60747-5-2 but neither certified nor inspected to IEC60747-5-2. The Si85xx is
compliant, certified, and factory-inspected to IEC60950.
Table 6. IEC Safety Limiting Values1
Parameter
Case Temperature
Safety Input Current
Device Power Dissipation2
Symbol
TS
IS
PD
Test Condition
SOIC-20 Unit
150
°C
JA = 85, VDD = 5.5 V,
30
A
IIN to IOUT = 20 A,
TJ = 150 °C, TA = 25 °C
0.9
W
Notes:
1. Maximum value allowed in the event of a failure. Refer to the thermal derating curve in Figure 1.
2. The Si85xx is tested with VDD = 5.5 V, TJ = 150 ºC, CL = 15 pF, and with an input current from IIN to IOUT equal to
20 Amps at 500 kHz (duty cycle = 50%).
Preliminary Rev. 0.4