SI8513-C-IS Datasheet, PDF (5/37 Pages) List of Unclassifed Manufacturers – Si85XX UNIDIRECTIONAL AC CURRENT SENSORS | |||
|
◁ |
Si85xx
Table 1. Electrical Specifications (Continued)
TA = â40 to +125 ºC (typical specified at 25 ºC), VDD = 3 V (±10%) to 5 V (±10%), f = 400 kHz, unless specified
Parameter
Conditions
Min Typ Max
OUT, OUT1, OUT2 Offset Voltage
(VOUTMIN)
VOUT Slew Rate1,2
Current flow from IIN to IOUT = 0
â
50
â
OUT, OUT1, OUT2 load = 5K || 50 pF â
50
â
OUT, OUT1, OUT2 Output Resistance
20
â 130
Total Measurement Error (%)
(â40 to 125 ºC Temp Range)
20% of full scale3,4 (all devices)
â30
â
+30
100% of full scale3,4
â10 â +10
Notes:
1. Guaranteed by design and/or characterization.
2. Maximum output load is not recommended to exceed 200 pF and 5 kï.
3. Production tested at 400 kHz (50% duty cycle) at VDD = 3.3 V.
4. See "2.4. Total Measurement Error" on page 11 for more information.
Unit
mV
V/µs
ï
%
%
Table 2. Regulatory Information1 (SOIC-20 Only)
CSA
The Si85xx is certified under CSA Component Acceptance Notice 5A. For more details, see File 232873.
VDE2
The Si85xx is certified according to IEC 60747-5-2. For more details, see File 5006301-4880-0001.
UL
The Si85xx is certified under UL1577 component recognition program. For more details, see File E257455.
Notes:
1. All 5.0 kVRMS rated devices are production tested to >6.0 kVRMS for 1 sec. For more information, see "6. Ordering
Guide" on page 26.
2. Pending.
Preliminary Rev. 0.4
5
|
▷ |