English
Language : 

SI8513-C-IS Datasheet, PDF (18/37 Pages) List of Unclassifed Manufacturers – Si85XX UNIDIRECTIONAL AC CURRENT SENSORS
Si85xx
3.3.4. Setting Reset Time tR
The programmable reset timer is triggered when the states of the signals applied to R1–R4 cause the associated
logic expression in Table 11 to go high (transition to the TRUE state).
Because this timer is re-triggerable, R1–R4 must remain TRUE for the duration of the desired tR as shown in
Figure 15. Should R1–R4 transition FALSE during tR, integrator reset will be immediately halted, resulting in lower
measurement accuracy due to higher integrator offset error.
CURRENT
R1–R4 TRUE
for programmed
tR (minimum)
R1–R4 STATE
TRUE
Programmed
value of tR
0 ns (min)
FALSE
Si85xx STATUS RESET
MEASURE
Si85xx OUTPUT
Figure 15. Correct tR Programming Using Resistor from TRST Input to Ground
18
Preliminary Rev. 0.4