3.3.6. Output Over-Range
The Si85xx can be over-ranged by more than 100% with no adverse effects. For instance, if the Si8512 (a 10 A
nominal full-scale device) has a 15 A peak current applied, then the output voltage (OUT) will be 3 V (assuming
VDD = 5 V). If a 10 A peak current is applied, then the output returns to the nominal 2 V output. The head room of
OUT is VDD–1.4 V. Figure 17 illustrates the head room limitation of the Si85xx versus supply.
5
4
3
OUT (V)
2
3.6 V
VDD = 5 V
VDD = 2.7 V
1
0
50% 100% 150% 200% 250%
I (Amps) Percent Nominal Full-Scale Input
Figure 17. Headroom Limitation