SI8513-C-IS Datasheet, PDF (17/37 Pages) List of Unclassifed Manufacturers – Si85XX UNIDIRECTIONAL AC CURRENT SENSORS | |||
|
◁ |
Si85xx
As explained in Section â2.3. Integrator Reset and Current Measurementâ, the signals applied to R1âR4 can
control integrator reset in real time (Option 1), or they can trigger a reset event of programmable duration (Option
2). Referring to Figure 14, reset timing is exclusively a function of the signals applied to R1âR4 when TRST is tied
to VDD.
If not connected to VDD, the reset timer is enabled, and TRST must be connected through a resistor to ground to
set the reset duration (tR). Note that the reset timer is retriggerable and generates a timed integrator discharge
pulse whenever the reset logic output transitions from low to high.
R1
R2
R3
R4
MODE = 1
R4 = 0
MODE = 1
R4 = 1
Output 1
TRST = VDD
Reset timing determined
only by inputs R1âR4.
TRST = R1 to GND
Reset triggered by inputs
R1âR4. Reset time (tR) set
by value of resistor RTRST.
Output 2
RESET
TIMER
PGM
CLK OUT
TRST
MODE = 0
Output 3
10
+
VREF
SYSTEM
CONTROLLER
Logic level gate
control signals
(to Rn inputs)
Internal
Driver
Required if driver
output voltage > VDD
External
Driver
Logic level gate
control signals
(to Rn inputs)
INTEGRATOR
Figure 14. Si851x Integrator Reset Logic
Preliminary Rev. 0.4
17
|
▷ |