English
Language : 

ISE40-T1-22 Datasheet, PDF (7/17 Pages) List of Unclassifed Manufacturers – High Precision, Digital Pressure Switch
ZSE40/ISE40 High Precision,
Digital Pressure Switch Series
Unit Set
Output Type
It's only subject to ZSE40(F)/ISE40-„-„(L).
ON
Unit selection
[P]
≥
Set the unit by either į button or Ĭ button.
: kPa or MPa, : kgf/cm2,
: bar,
: psi,
: inHg,
: mmHg
OUT1
Output mode
∗ OUT2: Same as OUT1.
SET Press “SET” button.
OUT1: Selection of the output mode
≥
[N]
YES
NO
OFF
P-2 P-1
High pressure (for positive pressure/compound pressure)
High vacuum (for vacuum pressure)
Ǟ
Ȝ Hysteresis mode
H
ON
H
H (Fixed hysteresis) = 3 digits
OFF P-1
P-2
High pressure (for positive pressure/compound pressure)
Ǟ High vacuum (for vacuum pressure)
Ȝ Window comparator mode
ZSE„
ISE„
PSE
ZI SE3
YES
NO
ON
PS
OFF
n-2 n-1
High pressure (for positive pressure/compound pressure)
Ǟ High vacuum (for vacuum pressure)
Ȝ Hysteresis mode
H
ON
H
H (Fixed hysteresis) = 3 digits
OFF n-1
n-2
High pressure (for positive pressure/compound pressure)
Ǟ High vacuum (for vacuum pressure)
Ȝ Window comparator mode
ZI SE12
ZSP
ISA2
IS„
ZSM
Auto Preset (For adsorption confirmation)
1. Auto preset mode
2. Preparation for auto preset
3. Auto preset of OUT1
PF2„
IF„
SET
Press the “SET” button.
Data
Select the Auto preset mode in
the initial setting mode and
press the “SET” button until
“ ” is displayed.
Prepare the equipment for use
under operating conditions.
When setting OUT1 is not
required, press both the į
button and Ĭ button
simultaneously in this state to
skip to “ ”.
4. Preparation for auto preset
Repeat adsorption and non-
adsorption release several times
in this state.
The optimal set value is
determined automatically.
5. Auto preset of OUT2
High
Vacuum
Max. A
ON
Suction
Workpiece 1
Workpiece 2
Workpiece n
OFF
Min. B
Released
Workpiece 1
Workpiece 2
Workpiece n
Atmosphere
Max. A: Max. pressure value when a workpiece is adsorbed.
ON =
A
–
A–
4
B
Min. B: Min. pressure value when a workpiece is not adsorbed.
OFF
=
B
+
A
–
4
B
SET
Press the “SET” button.
SET
Press the “SET” button.
SET
Press the “SET” button
to complete the setting.
Supplies vacuum pressure,
changing the condition of a
workpiece by adsorption nozzle,
etc. When setting OUT2 is not
required, press both the į
button and Ĭ button
simultaneously in this state to
skip to the measurement mode.
Repeat adsorption and non-
adsorption several times in this
state.
The optimum set value is
determined automatically.
16-2-21