English
Language : 

ISE40-T1-22 Datasheet, PDF (3/17 Pages) List of Unclassifed Manufacturers – High Precision, Digital Pressure Switch
ZSE40/ISE40 High Precision,
Digital Pressure Switch Series
How to Order
Set pressure range
Nil –0.100 to 1.000 MPa For positive pressure
For positive pressure ISE40
For vacuum/compound pressure ZSE40
01 22
01 22
Set pressure range
Nil 10.0 to –101.3 kPa For vacuum pressure
F –100.0 to 100.0 kPa For compound pressure
Piping specifications
01: R 1/8 (With M5 female threads) W1: Rc 1/8
T1: NPT 1/8 (With M5 female threads)
R 1/8, NPT 1/8
Reverse pressure
two directions
Rc 1/8
M5 x 0.8 female threads
Rc 1/8
∗ C4: With ø4 One-touch fitting
∗ C6: With ø6 One-touch fitting
Wall mount
∗ M5: M5 x 0.8 (Female threads)
Wall mount
Option
Nil None
Bracket A
A
(ZS-24-A)
Bracket B
B
(ZS-24-B)
Panel mount (ZS-22-A)
E
ZSE„
ISE„
PSE
ZI SE3
PS
ZI SE12
ZSP
ISA2
IS„
ZSM
PF2„
IF„
Data
Panel mount (ZS-24-C)
+ Front protective cover
ø4, ø6
M5 x 0.8
F
One-touch fitting
∗ Option
Input/Output specifications
22 NPN open collector 2 outputs + analog output
30 ∗ NPN open collector 2 outputs + auto shift input
62 ∗ PNP open collector 2 outputs + analog output
70 ∗ PNP open collector 2 outputs + auto shift input
∗ Option
Note
When equipped with auto shift function, the following ranges can be set.
Set pressure range
–100.0 to 100.0 kPa
10.0 to –101.3 kPa
–0.1 to 1.000 MPa
Setting range
–100.0 to 100.0 kPa
–101.3 to 101.3 kPa
–1.000 to 1.000 MPa
∗ When optional parts only are
required, order with the part
numbers inside ( ).
Unit specifications
Nil With unit switching function Note1)
M
SI unit only Note 2)
Note 1) This will no longer be sold for use in
Japan after the new Weight and
Measure Act is implemented
(October,1999).
Note 2) Fixed unit
For vacuum/compound pressure: kPa
For positive pressure: MPa
Lead wire length
Nil 0.6 m
L 3m
16-2-17