ISE40-T1-22 Datasheet, PDF (2/17 Pages) List of Unclassifed Manufacturers – High Precision, Digital Pressure Switch
High speed response: 2.5 ms
or less
With anti-chattering function
Stable switch output is possible even with sudden
Anti-chattering function
Devices such as large bore cylinders and high-flow vacuum
ejectors consume a large volume of air when they operate, and
this may cause a momentary drop in the primary pressure. This
function prevents such momentary pressure drops from being
detected as abnormal pressures by allowing the response time
selection to be changed.
[Selectable response times: t]
2.5 ms (normal), 24 ms, 192 ms or 768 ms
The normal setting is selected when shipped from the factory.
(Operating principle)
The pressure values measured within the user-selected response
time are averaged, and switch output (ON/OFF) is determined by
comparing this averaged pressure value with the set pressure.
Pressure
Set value P1
P2
Switch output ON
operation
when normal OFF
Switch output
operation when ON
anti-chattering
function is used
OFF
Momentary change
t (ms)
(Averaging)
t (ms)
Time →
(Averaging)
Time →
Time →
With auto shift function
Allows switch output unaffected by variations in
primary pressure.
Auto shift function
Erroneous operation may occur if there is fluctuation in the
primary pressure.
The auto shift function compensates for pressure changes to
ensure proper ON/OFF switch response during such fluctuations.
(Operating principle)
At the point when the primary pressure fluctuates, the set
pressure value is compensated by setting the auto shift input
(external input) to low (no-voltage) input, using the pressure
measured at that point as a standard.
Without using auto shift
When the primary pressure fluctuates, a correct determination becomes impossible.
Pressure
Primary pressure normal Primary pressure drop Primary pressure increase
P1
Set value
P2
Switch output ON
1, 2
OFF
When using auto shift
Does not turn ON
Time →
Does not turn OFF
Time →
Set value compensation Set value compensation
Compound pressure (ZSE40F)
Able to detect suction pressure (vacuum
pressure) and release pressure (positive
pressure) with a single pressure switch.
Pressure
Primary pressure normal Primary pressure drop Primary pressure increase
P1
Set value
P2
Time →
3 types of piping
Different piping methods are
possible to accommodate the
installation location.
Switch output ON
1, 2
OFF
Hi
Auto shift
input
Lo
5 ms or more
10 ms
or less
Time →
[ ] Switch output response time
when auto shift is input.
Time →
Repeatability
±0.2% F.S. ±1 digit or less
16-2-16
IP65 compatible