English
Language : 

ISE40-T1-22 Datasheet, PDF (10/17 Pages) List of Unclassifed Manufacturers – High Precision, Digital Pressure Switch
Series ZSE40/ISE40
Dimensions
ZSE40(F)/ISE40–
C4
C6
M5
32.3
30
20
2-4.5
MPa
OUT1
OUT2
SET
Atmospheric
release port
7.8
2.6
ø3.5
For–M5
12.8
8
12
One-touch fitting ø4, ø6
M5 x 0.8 thread depth 5
∗ For splash proof use (IP65), insert an air tube into the atmospheric release port.
(Refer to “Precautions” for details.)
Precautions
Caution
1. Immediately after supplying power, there is drift of about ±0.5% F.S. When used
with very low pressure, allow the unit to warm up for about 20 to 30 minutes.
2. Do not use in locations where there is splashing or spraying of oils and solvents.
3. When using a commercially available switching regulator, be sure to ground the
FG terminal.
4. In locations where the switch is exposed to water and dust, etc., these may
enter the switch from the atmospheric release port. Insert ø4 tubing (inside
diameter ø2.5) into the atmospheric release port, and extend the other end to a
safe area where water, etc., is not splashed or sprayed. Be sure that tubing is
not bent and holes are not blocked, etc., or it will become impossible to make
correct pressure measurements.
MPa
OUT1
OUT2
SET
Atmospheric release port
Air tube
Recommended tubing (SMC)
TU0425 (Polyurethane)
16-2-24