SED1565 Series
DESCRIPTION OF FUNCTIONS
The MPU Interface
Selecting the Interface Type
With the SED1565 Series chips, data transfers are done
through an 8-bit bi-directional data bus (D7 to D0) or
through a serial data input (SI). Through selecting the P/
S terminal polarity to the “H” or “L” it is possible to
select either parallel data input or serial data input as
shown in Table 1.
P/S
H: Parallel Input
L: Serial Input
CS1 CS2
CS1 CS2
CS1 CS2
Table 1
A0 RD WR C86 D7 D6 D5~D0
A0 RD WR C86 D7 D6 D5~D0
A0 — — — SI SCL (HZ)
“—” indicates fixed to either “H” or to “L”
The Parallel Interface
When the parallel interface has been selected (P/S =
“H”), then it is possible to connect directly to either an
8080-system MPU or a 6800 Series MPU (as shown in
Table 2) by selecting the C86 terminal to either “H” or
to “L”.
Table 2
P/S
CS1 CS2 A0
H: 6800 Series MPU Bus CS1 CS2 A0
L: 8080 MPU Bus
CS1 CS2 A0
RD WR D7~D0
E R/W D7~D0
RD WR D7~D0
Moreover, data bus signals are recognized by a
combination of A0, RD (E), WR (R/W) signals, as
shown in Table 3.
Shared
A0
1
1
0
0
6800 Series
R/W
1
0
1
0
Table 3
8080 Series
RD
WR
0
1
1
0
0
1
1
0
Function
Reads the display data
Writes the display data
Status read
Write control data (command)
8–24