English
Language : 

E1729E30 Datasheet, PDF (15/33 Pages) Elpida Memory – 1G bits DDR3 SDRAM
EDJ1108DJBG, EDJ1116DJBG
Table 8: IDD2N and IDD3N Measurement-Loop Pattern
CK,
Sub Cycle Com-
A11
A7 A3 A0
/CK
CKE -Loop number mand /CS /RAS /CAS /WE ODT BA*3 -Am A10 -A9 -A6 -A2 Data*2
0
D
1
0
0
0
0
0
0
0
0 00
1
0
2
D
1
0
0
0
0
0
0
0
0 00
/D
1
1
1
1
0
0
0
0
0 F0
3
/D
1
1
1
1
0
0
0
0
0 F0
1
4 to 7 Repeat Sub-Loop 0, use BA= 1 instead
Toggling Static H 2
8 to 11 Repeat Sub-Loop 0, use BA= 2 instead
3
12 to 15 Repeat Sub-Loop 0, use BA= 3 instead
4
16 to 19 Repeat Sub-Loop 0, use BA= 4 instead
5
20 to 23 Repeat Sub-Loop 0, use BA= 5 instead
6
24 to 27 Repeat Sub-Loop 0, use BA= 6 instead
7
28 to 31 Repeat Sub-Loop 0, use BA= 7 instead
Notes: 1.
2.
3.
4.
DM must be driven low all the time. DQS, /DQS are MID-LEVEL.
DQ signals are MID-LEVEL.
BA: BA0 to BA2.
Am: m means Most Significant Bit (MSB) of Row address.
Table 9: IDD2NT and IDDQ2NT Measurement-Loop Pattern
CK,
Sub Cycle Com-
A11
A7 A3 A0
/CK
CKE -Loop number mand /CS /RAS /CAS /WE ODT BA*3 -Am A10 -A9 -A6 -A2 Data*2
0
D
1
0
0
0
0
0
0
0
0 00
1
0
2
D
1
0
0
0
0
0
0
0
0 00
/D
1
1
1
1
0
0
0
0
0 F0
3
/D
1
1
1
1
0
0
0
0
0 F0
1
4 to 7 Repeat Sub-Loop 0, but ODT = 0 and BA= 1
Toggling Static H 2
8 to 11 Repeat Sub-Loop 0, but ODT = 1 and BA= 2
3
12 to 15 Repeat Sub-Loop 0, but ODT = 1 and BA= 3
4
16 to 19 Repeat Sub-Loop 0, but ODT = 0 and BA= 4
5
20 to 23 Repeat Sub-Loop 0, but ODT = 0 and BA= 5
6
24 to 27 Repeat Sub-Loop 0, but ODT = 1 and BA= 6
7
28 to 31 Repeat Sub-Loop 0, but ODT = 1 and BA= 7
Notes: 1.
2.
3.
4.
DM must be driven low all the time. DQS, /DQS are MID-LEVEL.
DQ signals are MID-LEVEL.
BA: BA0 to BA2.
Am: m means Most Significant Bit (MSB) of Row address.
Data Sheet E1729E30 (Ver. 3.0)
15