English
Language : 

STC3800_15 Datasheet, PDF (28/48 Pages) Connor-Winfield Corporation – INTEGRATED - STRATUM 3E TIMING SOURCE
Performance Specifications continued
Wander Transfer – Wander transfer is the degree to which input wander is attenuated (or amplified) from input to
output of a clock. The GR-1244 requirements for wander transfer limits are shown below.
Integration time, τ (seconds)
τ < 0.05
0.05 ≤ τ < 0.1
0.1 ≤ τ < 1.44
1.44 ≤ τ < 10
10 ≤ τ < 300
300 ≤ τ ≤ 1000
1000 < τ
Stratum 3 TDEV (nanoseconds)
N/A
1020 x τ
102
102
32.2 x τ 0.5
32.2 x τ 0.5
N/A
Stratum 3E TDEV (nanoseconds)
N/A
Ν/Α
3.16 x τ 0.5
1.86 x τ
1.86 x τ
32.2 x τ 0.5
N/A
The STC3800, when configured for the appropriate stratum 3 bandwidth frequency, meets the stratum 3 requirements,
Jitter Generation – Jitter generation is the process whereby jitter appears at the output of a clock in the absence of
input jitter.
The device jitter generation performance is as shown below:
Jitter
Broadband
500 Hz - 1.3 MHz
65 kHz - 1.3 MHz
STC3800 Performance
< 6 pS RMS, < 50 pS p-p
< 1.5 pS RMS
< 1 pS RMS
Requirement, p-p
T1/E1:32 nS
T1/E1: 32 nS, STM-1: 3.21nS
T1/E1: 32 nS, STM-1: 643 pS
Jitter Transfer – Jitter transfer is the degree to which input jitter is attenuated (or amplified) from input to output of a
clock. It is a function of the selected bandwidth. The STC3800 jitter transfer characteristics are shown below:
10 dB
5 dB
0 dB
-5 dB
-10 dB
-15 dB
fc=0.77 mHz
-20 dB
-25 dB
-30 dB
-35 dB
-40 dB
-45 dB
-50 dB
100 mHz 1 mHz
Jitter Transfer Characteristics
fc=1.6Hz
<
Bandwidth (fc)
0.77 mHz
1.5 mHz
3.1 mHz
6.1 mHz
0.012 Hz
0.025 Hz
0.049 Hz
0.098 Hz
0.20 Hz
0.39 Hz
0.78 Hz
1.6 Hz
10 mHz
100 mHz
1 Hz
10 Hz
Jitter Modulation Frequency
100 Hz
1 kHz
Preliminary Data Sheet #: TM061 Page 28 of 48 Rev: P06 Date: 11/22/04
© Copyright 2001 The Connor-Winfield Corp. All Rights Reserved Specifications subject to change without notice