1.6.2 Receive Frame Examples
The operations needed to receive a single Frame consisting of Symbol and Frame Sync sequences, Station ID
block and one each Header, Intermediate and Last blocks are shown below;
1.
Ensure that the Control Register has been loaded with suitable CKDIV, FSTOL, LEVRES and
PLLBW valus, and that the IRQNEN bit of the Mode Register is '1', the TXRXN, RXEYE, PSAVE and
SSIEN bits are '0', and the INVSYM bit is set appropriately.
2.
Wait until the received carrier has been present for at least 8 symbol times (see Section 1.6.3).
3.
Read the Status Register to ensure that the BFREE bit is '1'.
4.
Write a byte containing a SFP task with the AQSC and AQLEV bits set to '1' to the Command
Register.
5.
Wait for an interrupt from the modem, read the Status Register; the IRQ and BFREE bits should be
'1' and the CRCERR and DIBOVF bits should be '0'.
6.
Read 3 Station ID bytes from the Data Block Buffer.
7.
Write a RHB task to the Command Register.
8.
Wait for an interrupt from the modem, read the Status Register; the IRQ and BFREE bits should be
'1' and the DIBOVF bit '0'.
9.
Check that the CRCERR bit of the Status Register is '0' and read 10 Header Block bytes from the
Data Block Buffer.
10 Write a RILB task to the Command Register.
11. Wait for an interrupt from the modem, read the Status Register; the IRQ and BFREE bits should be
'1' and the DIBOVF bit '0'.
12. Read 12 Intermediate Block bytes from the Data Block Buffer.
13. Write a RILB task to the Command Register.
14. Wait for an interrupt from the modem, read the Status Register; the IRQ and BFREE bits should be
'1' and the DIBOVF bit '0'.
15. Check that the CRCERR bit of the Status Register is '0' and read the 8 Last Block bytes from Data
Buffer.
Note: The value of the latest 'S' symbol received will be contained in the SVAL bits each time that the Status
Register is read. If desired, the Mode Register SSIEN bit may be set to '1', which will cause a µC interrupt after
every 'S' symbol is received - in which case the µC will have to distinguish between interrupts caused by the
BFREE bit going to '1', and those caused by the SRDY bit being set to '1'.