3. CHARACTERISTICS AND SPECIFICATIONS
CS2100-OTP
RECOMMENDED OPERATING CONDITIONS
GND = 0 V; all voltages with respect to ground. (Note 1)
Parameters
Symbol Min Typ Max Units
DC Power Supply
VD
3.1
3.3
3.5
V
Ambient Operating Temperature (Power Applied)
Commercial Grade TAC
-10
-
+70
°C
Notes: 1. Device functional operation is guaranteed within these limits. Functionality is not guaranteed or implied
outside of these limits. Operation outside of these limits may adversely affect device reliability.
ABSOLUTE MAXIMUM RATINGS
GND = 0 V; all voltages with respect to ground.
Parameters
DC Power Supply
Input Current
Digital Input Voltage (Note 1)
Ambient Operating Temperature (Power Applied)
Storage Temperature
Symbol
Min
VD
-0.3
IIN
-
VIN
-0.3
TA
-55
Tstg
-65
Max
6.0
±10
VD + 0.4
125
150
Units
V
mA
V
°C
°C
WARNING: Operation at or beyond these limits may result in permanent damage to the device.
Notes: 1. The maximum over/under voltage is limited by the input current except on the power supply pin.
DC ELECTRICAL CHARACTERISTICS
Test Conditions (unless otherwise specified): VD = 3.1 V to 3.5 V; TA = -10°C to +70°C (Commercial Grade).
Parameters
Symbol Min Typ Max Units
Power Supply Current - Unloaded
Power Dissipation - Unloaded
Input Leakage Current
Input Capacitance
High-Level Input Voltage
Low-Level Input Voltage
High-Level Output Voltage (IOH = -1.2 mA)
Low-Level Output Voltage (IOH = 1.2 mA)
(Note 2)
(Note 2)
ID
PD
IIN
IC
VIH
VIL
VOH
VOL
-
12
18
mA
-
40
60
mW
-
-
±10
µA
-
8
-
pF
70%
-
-
VD
-
-
30%
VD
80%
-
-
VD
-
-
20%
VD
Notes: 2.
To calculate the additional current consumption due to loading (per output pin), multiply clock output
frequency by load capacitance and power supply voltage.
For example, fCLK_OUT (49.152 MHz) * CL (15 pF) * VD (3.3 V) = 2.4 mA of additional current due to