English
Language : 

CDB5376 Datasheet, PDF (30/78 Pages) Cirrus Logic – Multichannel Seismic Evaluation System
CDB5376
A microcontroller software connection is made when the SYNC_MC signal output is created by the micro-
controller on command from the system telemetry. The microcontroller can use an internal counter to re-
time the SYNC_MC signal output to the digital filter SYNC input as required.
2.3.6.2 I2C - SCL, SDA, Bypass
The I2C® telemetry connections to CDB5376 transmit and receive through RS-485 twisted pairs. Because
signals passing through the transceivers are actively buffered, full I2C bus arbitration and error detection
cannot be used (i.e. high-impedance NACK).
The I2C inputs and outputs can be externally wired to create either a daisy chain or a bus-type network,
depending how the telemetry system is to be implemented. Analog switches included on CDB5376 can
bypass the I2C signals to create a bus network from a daisy chain network following address assignment.
Specification
I2C Inputs, 2 wires each
I2C Outputs, 2 wires each
I2C Bypass Switch Control
Value
SCL±, SDA±
BYP_SCL±, BYP_SDA±
BYP_EN
When CDB5376 is used in a distributed measurement network, each node must have a unique address.
This address is used to transmit individual configuration commands and tag the source of returned con-
version data. Address assignment can be either dynamic or static, depending how the telemetry system
is to be implemented.
Dynamic address assignment uses daisy-chained I2C connections to assign an address to each mea-
surement node. Once a node receives an address, it enables the I2C bypass switches to the next node
so it can be assigned an address.
Static address assignment has a serial number assigned to each node during manufacturing. When
placed in the network, the location is recorded and a master list of serial numbers vs. location is main-
tained. Alternately, a location-dependent serial number can be assigned during installation.
2.3.7 UART Connection
A UART connection on CRD5376 provides a low-speed standardized connection for telemetry solutions
not using I2C. UART connections are provided for custom programming convenience only and are not
directly supported by the CDB5376 PC evaluation software or microcontroller firmware.
Specification
UART Connections, 2 wires each
Value
TX/GND, RX/GND
30
DS612DB2