English
Language : 

DDC232 Datasheet, PDF (21/28 Pages) Burr-Brown (TI) – 32-Channel, Current-Input Analog-to-Digital Converter
www.ti.com
Cascading Multiple Converters
Multiple DDC232 units can be connected in serial
configuration; see Figure 18.
DOUT can be used with DIN to daisy-chain multiple
DDC232 devices together to minimize wiring. In this
mode of operation, the serial data output is shifted
through multiple DDC232s; see Figure 18.
DDC232
SBAS331C – AUGUST 2004 – REVISED SEPTEMBER 2006
Figure 19 shows the timing diagram when the DIN
input is used to daisy-chain several devices.
Table 10 gives the timing specification for data
retrieval using DIN.
Data Clock
Data
Retrieval DOUT DDC232
DIN DOUT DDC232
DIN DOUT DDC232
DIN DOUT DDC232
DIN
Output
Sensor
CLK
Figure 18. Daisy-Chained DDC232s
DVALID
DCLK
DIN
tSTDIDC
tHDDIDC
DOUT
Input
128
MSB
Input
128
LSB
Input
127
MSB
Input 3 Input 2
LSB MSB
Input 2 Input 1
LSB MSB
Input 1
LSB
Figure 19. Timing Diagram When Using DDC232 DIN Function; See Figure 18
Table 10. Timing for DDC232 Data Retrieval Using DIN
SYMBOL
tSTDIDC
tHDDIDC
DESCRIPTION
Set-Up Time from DIN to Falling Edge of DCLK
Hold Time for DIN After Falling Edge of DCLK
MIN
TYP
10
10
MAX
Input
128
MSB
UNITS
ns
ns
Submit Documentation Feedback
21