English
Language : 

TMD4903 Datasheet, PDF (62/86 Pages) ams AG – Color and Proximity Sensor Module with mobeam
TMD4903 − ApplicationInformation
Figure 73:
Remote Control Registers and Fields
Control Registers
The remote control engine has 19 fields that govern pattern
timing and flow, output selection, and report status. All
pertinent fields are listed in the figure below.
Register / Bit
ENABLE<PON>
ENABLE<IBEN>
CFG0 <RAM_BANK>
PGCFG1 <PGLDRIVE>
STATUS <IINT>
ICONFIG <IIEN>
ICONFIG2 <IINVERT>
ICONFIG2 <IOUTPUT>
ICONFIG2 <IRCDCMODE>
ICONFIG2 <IDUTY>
ISNL <ISNL>
ISOFF <ISOFF>
IPNL <IPNL>
IPOFF <IPOFF>
IBT <IBT>
ISTATUS <IINT>
ISTATUS <IBUSY>
ISTART <ISTARTREMCON>
INTCLEAR <INTCLEAR_IINT>
Address
0x80<0>
0x80<7>
0x8D<0>
0x8F<4:0>
0x93<3>
0xA0<5>
0xA1<5>
0xA1<4:3>
0xA1<2>
0xA1<1:0>
0xA2<7:0>
0xA3<7:0>
0xA4<7:0>
0xA5<7:0>
0xA6<5:0>
0xA8<1>
0xA8<0>
0xA9<1>
0xDE<3>
Description
Power On
IRBeam Enable
RAM Bank Select
LED Drive Strength
IRBeam Interrupt (mirrors ISTATUS<IINT>)
IRBeam Interrupt Enable
IRBeam Polarity Inversion
Output Select
DC Carrier Select
Duty Cycle Select
Number of Repeated Sub-pattern Loops
Pause between Sub-pattern Bursts
Number of Complete Pattern Loops
Pause between Pattern Bursts
Carrier Selection Time
IRBeam Interrupt
IRBeam Busy
Remote Control Start Pattern Burst
IRBeam Interrupt Clear
Pertinent Control Registers: Resources associated with Remote Control.
Page 62
Document Feedback
ams Datasheet
[v1-12] 2015-May-14