English
Language : 

TMD4903 Datasheet, PDF (36/86 Pages) ams AG – Color and Proximity Sensor Module with mobeam
TMD4903− RegisterDescription
Figure 42:
Status Register Two
Status Register Two (STATUS2 0x9E)
7
PVALID
6
AVALID
5
Reserved
4
ASAT_
DIGITAL
3
ASAT_
ANALOG
2
PGSAT_
ADC
1
PGSAT_
REFLECTIVE
0
PGSAT_
AMBIENT
Field
PVALID
AVALID
Reserved
ASAT_DIGITAL
ASAT_ANALOG
PGSAT_ADC
PGSAT_REFLECTIVE
PGSAT_AMBIENT
Bits
7
6
5
4
3
2
1
0
Description
Proximity Valid. Indicates that the proximity state has completed a
cycle since either an assertion of PEN or the last readout of PDATA.
ALS Valid. Indicates that the ALS state has completed a cycle since
either an assertion of AEN or the last readout of at least one the
CDATAL register.
Reserved.
ALS Digital Saturation. Indicates that the maximum counter value
has been reached. Maximum counter value depends on integration
time set in the ATIME register.
ALS Analog Saturation. Indicates that the intensity of ambient
light has exceeded the maximum integration level for the ALS
analog circuit.
Proximity ADC Saturation. Indicates that the maximum ADC value
has occurred.
Proximity Reflective Saturation. Indicates that the intensity of
reflected light has exceeded the maximum integration level for the
proximity analog circuit.
Proximity Ambient Saturation. Indicates that the intensity of
ambient light has exceeded the maximum integration level for the
proximity analog circuit.
Page 36
Document Feedback
ams Datasheet
[v1-12] 2015-May-14