Figure 27:
ALS Integration Time Register
7
6
5
TMD4903− RegisterDescription
ALS Integration Time Register (ATIME 0x81)
4
3
2
1
0
ATIME
Field
ATIME
Bits
Description
ALS Integration Time. Sets the internal integration time of ALS/Color analog to digital
converters in increments of 2.78ms. The power on reset value is 0xFF. The ADC
maximum count (or saturation) value depends on the integration time. It is the lesser
of either:
65535 (16-bit saturation) or
The result of equation: CountMAX = 1024 X CYCLES
VALUE
INTEGRATION TIME
MAX COUNTS
7:0
0xFF
0xF6
2.78ms
27.8ms
1024
10240
0xDC
100ms
36864
…
2.78ms X (256 - ATIME)
…
0xC0
178ms
65535
0x00
711ms
65535