EP2AGX125EF29I5N Datasheet, PDF (19/78 Pages) Altera Corporation – Device Datasheet for Arria II Devices | |||
|
◁ |
Chapter 1: Device Datasheet for Arria II Devices
Electrical Characteristics
1â19
Table 1â30 lists the HSTL I/O standards for Arria II GX devices.
Table 1â30. Differential HSTL I/O Standards for Arria II GX Devices
I/O Standard
HSTL-18 Class I
HSTL-15 Class I, II
HSTL-12 Class I, II
VCCIO (V)
VDIF(DC) (V)
Min Typ Max Min Max
1.71 1.8 1.89 0.2 â
1.425 1.5 1.575 0.2 â
1.14 1.2 1.26 0.16 â
VX(AC) (V)
Min Typ Max
0.85 â 0.95
0.71 â 0.79
â
0.5 Ã
VCCIO
â
VCM(DC) (V)
Min Typ Max
0.88 â 0.95
0.71 â 0.79
0.48
Ã
VCCIO
0.5 Ã
VCCIO
0.52 Ã
VCCIO
VDIF(AC) (V)
Min Max
0.4 â
0.4 â
0.3 â
Table 1â31 lists the HSTL I/O standards for Arria II GZ devices.
Table 1â31. Differential HSTL I/O Standards for Arria II GZ Devices
I/O Standard
HSTL-18 Class I
HSTL-15 Class I, II
VCCIO (V)
Min Typ Max
1.71 1.8 1.89
1.425 1.5 1.575
VDIF(DC) (V)
Min Max
0.2 â
0.2 â
VX(AC) (V)
Min Typ Max
0.78 â 1.12
0.68 â 0.9
HSTL-12 Class I, II
1.14
1.2
1.26
0.16
VCCIO
+ 0.3
â
0.5 Ã
VCCIO
â
VCM(DC) (V)
Min Typ Max
0.78 â 1.12
0.68 â
0.9
0.4 Ã
VCCIO
0.5 Ã
VCCIO
0.6 Ã
VCCIO
VDIF(AC) (V)
Min Max
0.4 â
0.4 â
VCCIO
0.3 +
0.48
Table 1â32 lists the differential I/O standard specifications for Arria II GX devices.
Table 1â32. Differential I/O Standard Specifications for Arria II GX Devices (Note 1)
I/O
Standard
VCCIO (V)
Min Typ Max
VID (mV)
VICM (V) (2)
Min Cond. Max Min Max
VOD (V) (3)
Min Typ Max
VOCM (V)
Min Typ Max
2.5 V
LVDS
2.375 2.5 2.625
100
VCM =
1.25 V
â
0.05 1.80 0.247 â
0.6
1.125 1.25 1.375
RSDS (4) 2.375 2.5 2.625 â
â â â â 0.1 0.2 0.6 0.5 1.2 1.4
Mini-LVDS
(4)
2.375
2.5 2.625
â
â â â â 0.25 â 0.6
1 1.2 1.4
LVPECL
(5)
2.375 2.5 2.625 300
â
â 0.6 1.8 â â â
âââ
BLVDS (6) 2.375 2.5 2.625 100 â â â â â â â â â â
Notes to Table 1â32:
(1) The 1.5 V PCML transceiver I/O standard specifications are described in âTransceiver Performance Specificationsâ on page 1â21.
(2) VIN range: 0 <= VIN <= 1.85 V.
(3) RL range: 90 <= RL <= 110 ï .
(4) The RSDS and mini-LVDS I/O standards are only supported for differential outputs.
(5) The LVPECL input standard is supported at the dedicated clock input pins (GCLK) only.
(6) There are no fixed VICM, VOD, and VOCM specifications for BLVDS. These specifications depend on the system topology.
July 2012 Altera Corporation
Arria II Device Handbook Volume 3: Device Datasheet and Addendum
|
▷ |