A row interconnect channel can be fed by the output of the macrocell
through a 4-to-1 multiplexer that the macrocell shares with three column
channels. If the multiplexer is used for a macrocell-to-row connection, the
three column signals can access another row channel via an additional
3-to-1 multiplexer. Within any LAB, the multiplexers provide all
48 column channels with access to 32 row channels.
Row-to-I/O Cell Connections
Figure 8 illustrates the connections between row interconnect channels
and IOCs. An input signal from an IOC can drive two separate row
channels. When an IOC is used as an output, the signal is driven by a
10-to-1 multiplexer that selects the row channels. Each end of the row
channel feeds up to eight IOCs on the periphery of the device.
Figure 8. MAX 9000 Row-to-IOC Connections
IOC1
10
Row FastTrack
Interconnect
96
96
96
10
IOC8
Each IOC is driven by
a 10-to-1 multiplexer.
Each IOC can drive up to
two row channels.
Column-to-I/O Cell Connections
Each end of a column channel has up to 10 IOCs (see Figure 9). An input
signal from an IOC can drive two separate column channels. When an IOC
is used as an output, the signal is driven by a 17-to-1 multiplexer that
selects the column channels.