English
Language : 

AK4133VN Datasheet, PDF (7/28 Pages) Asahi Kasei Microsystems – 192kHz 24bit Sample Rate Converter
[AK4133]
9. Consumption Current
■ Internal Regurator (VSEL pin= “L”)
(Ta= -40  105ºC)
Parameter
Symbol Min.
Power Supply Current
Normal operation:
FSI= FSO= 48kHz at Master Mode :
DVDD= 3.3V
-
DVDD= 3.6V
-
FSI= 96kH, FSO= 48kHz at Master Mode :
DVDD=3.3V
-
DVDD=3.6V
-
FSI= 192kH, FSO= 48kHz at Master Mode :
DVDD=3.3V
-
DVDD=3.6V
-
Power down: PDN = “L” (* 8)
DVDD=3.6V
-
Note:
* 8. All digital input pins including clock pins are connected to DVSS.
Typ. Max. Unit
6
-
mA
-
8
mA
10
-
mA
-
12
mA
16
-
mA
-
18
mA
10
100 A
■ External VD18 (VSEL pin= “H”)
(Ta= -40  105ºC)
Parameter
Symbol Min. Typ. Max. Unit
Power Supply Current
Normal operation:
FSI=FSO=48kHz at Master Mode:
DVDD=VD18=1.8V
-
6
-
mA
DVDD=VD18=1.9V
-
-
8
mA
FSI=96kH, FSO=48kHz at Master Mode:
-
DVDD=VD18=1.8V
-
10
-
mA
DVDD=VD18=1.9V
-
-
12 mA
FSI=192kH, FSO=48kHz at Master Mode:
DVDD=VD18=1.8V
-
16
-
mA
DVDD=VD18=1.9V
-
-
18 mA
Power down: PDN = “L” (* 9) DVDD=VD18=1.9V
-
10
100 A
Note:
* 9. Except the VSELL pin, all digital input pins including clock pins are connected to DVSS.
015015325-E-01
-7-
2016/06