f) Pressure detector 1 (EEPROM name: PTH1, HYS1)
The operating mode, the detection threshold values and the hysteresis voltage of the comparator
for the pressure detector 1 are individually set up.
The detector threshold voltage varies and the hysteresis voltage ratiometrically with respect to
the supply voltage.
f-1) Pressure detector operating mode setup
Address : 07 hex D[7:5] = EINV1[0], EINE1[0], EIN1L[0]
D[7:5] Symbol
Mode setup
D[7]
EINV1[0] Pressure detector output polarity setup EEPROM
0 EINV11 High output when detected (default)
1 EINV10 Low output when detected
D[6]
EINE1[0] Pressure detector enabled setup EEPROM
0 INT1E Pressure detector 1 enable (default)
1 INT1D Pressure detector 1 disable
D[5]
EIN1L[0] Pressure detector 1 detection threshold setup EEPROM
0 INT1< Detect pressure above threshold (default)
1 INT1> Detect pressure below threshold
Address : 09 hex D[7] = EPTH1[0]
D[7] Symbol
Mode setup
D[7] EPTH1[0] Pressure detector 1 detection threshold selection EEPROM
0 PTH1R EEPROM setup (default)
1 PTH1E DET2/PTH pin external setup
f-2) Pressure detector detection threshold adjustment
Address : 07 hex D[4:0]=EPT1[4:0]
EPT1[4:0]
Detection threshold (V)
Dec Hex
Bin
Detect threshold
ex. VDD:5V
-16 10
10000
0.900*VDD
4.500
-15 11
10001
0.875*VDD
4.375
-14 12
10010
0.850*VDD
4.250
::
:
:
:
-3 1D
11101
0.575*VDD
2.875
-2 1E
11110
0.550*VDD
2.750
-1 1F
11111
0.525*VDD
2.625
0
00
00000
0.500*VDD
2.500
1
01
00001
0.475*VDD
2.375
2
02
00010
0.450*VDD
2.250
::
:
:
:
14 0E
01110
0.150*VDD
0.750
15 0F
01111
0.125*VDD
0.625
Comments
Default
f-3) Comparator hysteresis voltage adjustment for pressure detection
Address : 09 hex D[1:0]=EHYS1[1:0]
EHYS1[1:0]
Dec Hex
Bin
Hysteresis voltage (mV)
Hysteresis voltage
ex. VDD:5V
Comments
2
2
10
0.030*VDD
150.0
3
3
11
0.040*VDD
200.0
0
0
00
0.050*VDD
250.0
Default
1
1
01
0.060*VDD
300.0
MSxxxxx-E-00
- 43 -
2011/12