English
Language : 

ZADCS0882 Datasheet, PDF (15/20 Pages) Zentrum Mikroelektronik Dresden AG – 8-Bit, 300ksps, Serial Output ADC Family
Datasheet
ZADCS0882/0842/0822 Family
Figure 13: 16-Clock External Clock Mode Conversion
nCS
SCLK
DIN
SSTRB
DOUT
1
8
1
S A2 A1
(Start)
Idle
A0
UNI/
BIP
SGL/
DIF
PD1
PD0
Acquire
8
1
8
1
Conversion
S
A2
A1
A0
UNI/
BIP
SGL/
DIF
PD1 PD0
Idle
Acquire
B7 B6 B5 B4 B3 B2 B1 B0
(MSB)
(LSB)
Zero filled
B7 B6
Figure 14: 11-Clock External Clock Mode Conversion
nCS
SCLK
1
8
DIN
SSTRB
S
A2
A1
A0
UNI/
BIP
SGL/
DIF
PD1
PD0
(Start)
Idle
Acquire
11 1
S
A2
A1
A0
UNI/
BIP
SGL/
DIF
PD1
PD0
Conversion
Acquire
11 1
S
A2
A1
A0
UNI/ SGL/
BIP DIF
Conversion
DOUT
B7 B6 B5 B4 B3 B2 B1 B0 Zero filled B7 B6 B5 B4 B3 B2 B1 B0
(MSB)
(LSB)
Internal Clock Mode
In Internal Clock Mode, the conversion starts at the falling
clock edge of the eighth control bit just as in External
Clock Mode. However, there are no further clock pulses
required at SCLK to complete the conversion. The con-
version clock is generated by an internal oscillator that
runs at approximately 3.3MHz. While the conversion is
running, the SSTRB signal is driven LOW. As soon as the
conversion is complete, SSTRB is switched to HIGH,
signaling that the conversion result can be read out on
the serial interface.
To shorten cycle times ZADCS08x2 family devices allow
interleaving of the read out process with the transmission
of a new control byte. Thus it is possible to read the con-
version result and to start a new conversion with just two
consecutive byte transfers, instead of thee bytes that
would have to be send without the interleaving function.
While the IC is performing a conversion in Internal Clock
Mode, the Chip Select signal (nCS) may be tied HIGH
allowing other devices to communicate on the bus. The
output driver at DOUT is switched into a high impedance
state while nCS is HIGH. The conversion time tCONV may
vary in the specified limits depending on the actual VDD
and temperature values.
16-Clocks per Conversion
Interleaving of the data read out process and transmis-
sion of a new Control Byte is also supported for External
Clock Mode operation. Figure 13 shows the transmission
timing for conversion runs using 16 clock cycles per run.
11-Clocks per Conversion
ZADCS08x2 family devices do also support a 11 clock
cycle conversion mode (see Figure 14). This is the fastest
conversion mode possible. In fact, the specified converter
sampling rate of 300ksps will be reached in this mode,
provided the clock frequency is set to 3.3MHz.
Usually micro controllers do not support this kind of 11 bit
serial communication transfers. However, specifically
designed digital state machines implemented in Field
Programmable Gate Arrays (FPGA) or Application Spe-
cific Integrated Circuits (ASIC) may use this operation
mode.
Digital Timing
In general the clock frequency at SCLK may vary from
0.1MHz to 3.3MHz. Considering all telegram pauses or
other interruptions of a continuous clock at SCLK, each
conversion must be completed within 1.2ms from the
falling clock edge of the eighth bit in the Control Byte.
Otherwise the signal that was captured during sam-
Copyright © 2008, ZMD AG, Rev. 1.1
All rights reserved. The material contained herein may not be reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner. The
Information furnished in this publication is preliminary and subject to changes without notice.
15/20