English
Language : 

X40430 Datasheet, PDF (21/24 Pages) Intersil Corporation – Triple Voltage Monitor with Integrated CPU Supervisor
X40430/X40431 – Preliminary Information
VTRIP1, VTRIP2, VTRIP3 Programming Specifications: VCC = 2.0–5.5V; Temperature = 25°C
Parameter
Description
Min.
tVPS
tVPH
tTSU
tTHD
tWC
tVPO
VP
VTRAN
Vta1
Vta2
Vtr
Vtv
tVPS
WDO Program Voltage Setup time
10
WDO Program Voltage Hold time
10
VTRIPX Level Setup time
10
VTRIPX Level Hold (stable) time
10
VTRIPX Program Cycle
10
Program Voltage Off time before next cycle
1
Programming Voltage
15
VTRIPX Set Voltage Range
2.0
Initial VTRIPX Set Voltage accuracy (VCC applied—VTRIPX)
-0.1
Subsequent VTRIPX Program Voltage accuracy [(VCC applied—Vta1)–VTRIPX) -25
VTRIPX Set Voltage repeatability (Successive program operations.)
-25
VTRIPX Set Voltage variation after programming (-40 to +85°C).
-25
WDO Program Voltage Setup time
10
Max.
18
4.75
+0.4
+25
+25
+25
Unit
µs
µs
µs
µs
ms
ms
V
V
V
mV
mV
mV
µs
REV 1.2.3 11/28/00
www.xicor.com
Characteristics subject to change without notice. 21 of 24