CRE6 (Default 0x00)
Bit 7 - 6: Reserved.
Bit 5 - 0: CIR Baud Rate Divisor. The clock base of CIR is 32khz, so that the baud rate is 32khz
divided by ( CIR Baud Rate Divisor + 1).
CRE7 (Default 0x00)
Bit 7 - 3: Reserved.
Bit 2:Reset CIR Power-On function. After using CIR power-on, the software should
write logical 1 to restart CIR power-on function.
Bit 1: Invert RX Data.
= 1 Inverting RX Data.
= 0 Not inverting RX Data.
Bit 0: Enable Demodulation.
= 1 Enable received signal to demodulate.
= 0 Disable received signal to demodulate.
CRF0 (Default 0x00)
Bit 7: CHIPPME. Chip level auto power management enable.
= 0 disable the auto power management functions
= 1 enable the auto power management functions.
Bit 6: CIRPME. Consumer IR port auto power management enable.
= 0 disable the auto power management functions
= 1 enable the auto power management functions.
Bit 5: MIDIPME. MIDI port auto power management enable.
= 0 disable the auto power management functions
= 1 enable the auto power management functions.
Bit 4: Reserved. Return zero when read.
Bit 3: PRTPME. Printer port auto power management enable.
= 0 disable the auto power management functions.
= 1 enable the auto power management functions.
Bit 2: FDCPME. FDC auto power management enable.
= 0 disable the auto power management functions.
= 1 enable the auto power management functions.
Bit 1: URAPME. UART A auto power management enable.
= 0 disable the auto power management functions.
= 1 enable the auto power management functions.
Bit 0: URBPME. UART B auto power management enable.