W83697HF_05 Datasheet, PDF (31/102 Pages) Winbond – LPC I/O
W83697HF
THYST
127'C
TOI
TOI
THYST
SMI#
*
*
*
SMI#
*
*
*
*
*Interrupt Reset when Interrupt Status Registers are read
Figure 9.8
Figure 9.9
6.5.4 The W83697HF temperature sensor 2 SMI# interrupt has two modes and it is
programmed at CR[4Ch] bit 6.
(1) Comparator Interrupt Mode
Temperature exceeding TO causes an interrupt and this interrupt will be reset by reading all the
Interrupt Status Register. Once an interrupt event has occurred by exceeding TO, then reset, if
the temperature remains above the THYST, the interrupt will occur again when the next conversion
has completed. If an interrupt event has occurred by exceeding TO and not reset, the interrupts
will not occur again. The interrupts will continue to occur in this manner until the temperature
goes below THYST. (Figure 9.10)
(2) Two-Times Interrupt Mode
Temperature exceeding TO causes an interrupt and then temperature going below THYST will also
cause an interrupt if the previous interrupt has been reset by reading all the interrupt Status
Register. Once an interrupt event has occurred by exceeding TO, then reset, if the temperature
remains above the THYST, the interrupt will not occur. (Figure 9.11)
TOI
TOI
THYST
THYST
SMI#
*
*
**
SMI#
*
*
*
*
Figure 9.10
*Interrupt Reset when Interrupt Status Registers are read
Figure 9.11
- 28 -