The W77C032 can be woken from the Power Down mode by forcing an external interrupt pin
activated, provided the corresponding interrupt is enabled, while the global enable(EA) bit is set and
the external input has been set to a level detect mode. If these conditions are met, then the low level
on the external pin re-starts the oscillator. Then device executes the interrupt service routine for the
corresponding external interrupt. After the interrupt service routine is completed, the program
execution returns to the instruction after the one which put the device into Power Down mode and
continues from there. When RGSL(EXIF.1) bit is set to 1, the CPU will use the internal RC oscillator
instead of crystal to exit Power Down mode. The microcontroller will automatically switch from RC
oscillator to crystal after clock is stable. The RC oscillator runs at approximately 2−4 MHz. Using RC
oscillator to exit from Power Down mode saves the time for waiting crystal start-up. It is useful in the
low power system which usually be awakened from a short operation then returns to Power Down
mode.
Table 5. Status of external pins during Idle and Power Down
MODE
PROGRAM
MEMORY
ALE
PSEN PORT0
Idle
Internal
1
1
Data
Idle
External
1
1
Float
Power Down
Internal
0
0
Data
Power Down
External
0
0
Float
PORT1
Data
Data
Data
Data
PORT2 PORT3
Data
Address
Data
Data
Data
Data
Data
Data