W77C32/W77C032A
comparison. This register enables the Automatic Address Recognition feature of the Serial
port 1. When all the bits of SADEN1 are 0, interrupt will occur for any incoming address.
Serial Port Control 1
Bit:
7
6
5
4
3
2
SM0_1/FE_1 SM1_1 SM2_1 REN_1 TB8_1 RB8_1
1
TI_1
0
RI_1
Mnemonic: SCON1
Address: C0h
SM0_1/FE_1: Serial port 1, Mode 0 bit or Framing Error Flag 1: The SMOD0 bit in PCON SFR
determines whether this bit acts as SM0_1 or as FE_1. the operation of SM0_1 is
described below. When used as FE_1, this bit will be set to indicate an invalid stop bit.
This bit must be manually cleared in software to clear the FE_1 condition.
SM1_1: Serial port 1 Mode bit 1:
SM0_1 SM1_1 Mode Description
0 0 0 Synchronous
0 1 1 Asynchronous
1 0 2 Asynchronous
1 1 3 Asynchronous
Length
8
10
11
11
Baud rate
4/12 Tclk
variable
64/32 Tclk
variable
SM2_1: Multiple processors communication. Setting this bit to 1 enables the multiprocessor
communication feature in mode 2 and 3. In mode 2 or 3, if SM2_1 is set to 1, then RI_1 will
not be activated if the received 9th data bit (RB8_1) is 0. In mode 1, if SM2_1 = 1, then RI_1
will not be activated if a valid stop bit was not received. In mode 0, the SM2_1 bit controls the
serial port 1 clock. If set to 0, then the serial port 1 runs at a divide by 12 clock of the oscillator.
This gives compatibility with the standard 8052. When set to 1, the serial clock become divide
by 4 of the oscillator clock. This results in faster synchronous serial communication.
REN_1: Receive enable: When set to 1 serial reception is enabled, otherwise reception is
disabled.
TB8_1: This is the 9th bit to be transmitted in modes 2 and 3. This bit is set and cleared by software as
desired.
RB8_1: In modes 2 and 3 this is the received 9th data bit. In mode 1, if SM2_1 = 0, RB8_1 is the stop
bit that was received. In mode 0 it has no function.
TI_1: Transmit interrupt flag: This flag is set by hardware at the end of the 8th bit time in mode 0, or
at the beginning of the stop bit in all other modes during serial transmission. This bit must be
cleared by software.
RI_1: Receive interrupt flag: This flag is set by hardware at the end of the 8th bit time in mode 0, or
halfway through the stop bits time in the other modes during serial reception. However the
restrictions of SM2_1 apply to this bit. This bit can be cleared only by software
Serial Data Buffer 1
Bit:
7
6
SBUF1.7 SBUF1.6
5
SBUF1.5
4
SBUF1.4
3
SBUF1.3
2
SBUF1.2
1
SBUF1.1
0
SBUF1.0
Mnemonic: SBUF1
Address: C1h
- 20 -