W972GG6JB Datasheet, PDF (41/87 Pages) Winbond – 16M  8 BANKS  16 BIT DDR2 SDRAM
W972GG6JB
Operating Burst Read Current
All banks open, Continuous burst reads, IOUT = 0 mA;
BL = 4, CL = CL(IDD), AL = 0;
IDD4R tCK = tCK(IDD); tRAS = tRASmax(IDD), tRP = tRP(IDD);
195
170
155
mA
1,2,3,4,5,
6
CKE is HIGH, CS is HIGH between valid commands;
Address inputs are SWITCHING;
Data Bus inputs are SWITCHING.
Operating Burst Write Current
All banks open, Continuous burst writes;
BL = 4, CL = CL(IDD), AL = 0;
IDD4W tCK = tCK(IDD); tRAS = tRASmax(IDD), tRP = tRP(IDD);
155
150
140
mA
1,2,3,4,5,
6
CKE is HIGH, CS is HIGH between valid commands;
Address inputs are SWITCHING;
Data Bus inputs are SWITCHING.
Burst Refresh Current
tCK = tCK(IDD);
Refresh command every tRFC(IDD) interval;
IDD5B CKE is HIGH, CS is HIGH between valid commands;
175
160
150
mA
1,2,3,4,5,
6
Other control and address inputs are SWITCHING;
Data bus inputs are SWITCHING.
Distributed Refresh Current
tCK = tCK(IDD);
Refresh command every tREFI = 7.8 μS interval;
IDD5D CKE is LOW, CS is HIGH between valid commands;
16
16
16
mA
1,2,3,4,5,
6
Other control and address inputs are SWITCHING;
Data bus inputs are SWITCHING.
Self Refresh Current
IDD6
CKE ≤ 0.2 V, external clock off, CLK and CLK at 0 V;
Other control and address inputs are FLOATING;
12
12
12
mA
1,2,3,4,5,
6,7
Data bus inputs are FLOATING. (TCASE ≤ 85°C)
Operating Bank Interleave Read Current
All bank interleaving reads, IOUT = 0mA;
BL = 4, CL = CL(IDD), AL = tRCD(IDD) - 1 x tCK(IDD);
tCK = tCK(IDD), tRC = tRC(IDD), tRRD = tRRD(IDD), tRCD
IDD7
= tRCD(IDD);
310
250
220
mA
1,2,3,4,5,
6
CKE is HIGH, CS is HIGH between valid commands;
Address bus inputs are STABLE during deselects;
Data Bus inputs are SWITCHING.
Notes:
1. VDD = 1.8 V  0.1V; VDDQ = 1.8 V  0.1V.
2. IDD specifications are tested after the device is properly initialized.
3. Input slew rate is specified by AC Parametric Test Condition.
4. IDD parameters are specified with ODT disabled.
5. Data Bus consists of DQ, LDM, UDM, LDQS, LDQS , UDQS and UDQS .
6. Definitions for IDD
LOW = Vin ≤ VIL (ac) (max)
HIGH = Vin ≥ VIH (ac) (min)
STABLE = inputs stable at a HIGH or LOW level
FLOATING = inputs at VREF = VDDQ/2
SWITCHING = inputs changing between HIGH and LOW every other clock cycle (once per two clocks) for address and
control signals, and inputs changing between HIGH and LOW every other data transfer (once per clock)
for DQ signals not including masks or strobes.
7. The following IDD values must be derated (IDD limits increase), when TCASE ≥ 85°C IDD2P must be derated by 20%;
IDD3P(slow) must be derated by 30% and IDD6 must be derated by 80%. (IDD6 will increase by this amount if TCASE < 85°C
and the 2X refresh option is still enabled)
- 41 -
Publication Release Date: Nov. 29, 2011
Revision A02