English
Language : 

W83L784R_05 Datasheet, PDF (34/52 Pages) Winbond – Monitoring IC
W83L784R/ W83L784G
FANIN1/GPO1, FANIN2/GPO2 and BEEP/GPO3 Control Register -- Index 52h,,continued.
BIT NAME
0 EN_GPO1
READ/WRITE
Read/Write
DESCRIPTION
Enable GPO1 Function. Which enable multiple function pin
1, named FANIN1/GPO1, GPO1 function. Set to 0 (default),
pin 1 (FANIN1/GPO1) acts as FANIN1 whcih is fan clock
input. Set to 1, this pin 1 acts as GPO1 control function and
the output value of GPO1 is programmed by this register bit
1. This output pin GPO2 can connect to power PMOS gate to
control FAN ON/OFF.
7.19 CPUT1/CPUT2 Thermal Sensor Type Register -- Index 53h
Power on default [7:0] = 0000-0000 b
BIT
NAME
7-4 Reserved
3-2 T3_TYPE[1:0]
1-0 T2_TYPE[1:0]
READ/WRITE
Read/Write
Read/Write
Read/Write
DESCRIPTION
Reserved.
Temperature sensor 3 (CPU T2) type.
0x - Thermistor (10K @ 25 degree C, B=3435).
10 - 2N3904 transistor.
11 - Intel thermal diode.
Temperature sensor 2 (CPU T1) type.
0x - Thermistor (10K @ 25 degree C, B=3435)
10 - 2N3904 transistor
11 - Intel thermal diode.
7.20 Misc Control Register -- Index 54h
Power on default [7:0] = 0000-0000 b
BIT
NAME
READ/WRITE
DESCRIPTION
7-6 Reserved
Read/Write Reserved.
5 PWM2_LM_Enable Read/Write
Set 1, PWMOUT2 duty cycle will decrease to CR
[89h] when temperature goes below target range.
Set 0, PWMOUT2 duty cycle will decrease to 0 when
temperature grows below target range.
4 PWM1_LM_Enable Read/Write
Set 1, PWMOUT1 duty cycle will decrease to CR
[88h] when temperature goes below target range.
Set 0, PWMOUT1 duty cycle will decrease to 0 when
temperature grows below target range.
3 Reserved
Reserved
Reserved
2 SWP_FAN2_PWM Read/Write
Swap CPUT2 PWM to internal temperature sensor
PWM Control. Write this bit set to 1, FAN2 PWM
PWM control will refer to internal temperature sensor.
- 29 -
Publication Release Date: Jan. 2005