English
Language : 

W83L784R_05 Datasheet, PDF (26/52 Pages) Winbond – Monitoring IC
W83L784R/ W83L784G
7. REGISTERS AND RAM
7.1 Configuration Register -- Index 40h
Power on default [7:0] = 0000, 0001 b
BIT
NAME
READ/WRITE
DESCRIPTION
7 INITIALIZATION Read/Write
A one restores power on default value to all registers
except the Serial Bus Address register. This bit clears
itself since the power on default is zero.
6-4 Reserved
Read/Write Reserved
3 DIS_PWROK
Read/Write
Disable Power OK Function. If this bit set to 1, the
PWR_DN# (Pin 6) will keep logical high no mater what
the pwoer VDD or +3.3V drop to the threshold voltage
(4.0v and 2.6v, respectively).
2 Reserved
Reserved
Reserved
1 INT_ Clear
Read/Write
A one disables the SMI# outputs without affecting the
contents of Interrupt Status Registers. The device will
stop monitoring. It will resume upon clearing of this bit.
0 Start
Read/Write
A one enables startup of monitoring operation, a zero
puts the part in standby mode.
Note: The outputs of Interrupt pins will not be cleared if
the user writes a zero to this location after an interrupt
has occurred unlike "INT_Clear'' bit.
7.2 Interrupt Status Register 1 -- Index 41h
Power on default [7:0] = 0000, 0000 b
BIT
NAME
7 TEMP3
6 TEMP2
5 TEMP1
4 Reserved
3 VCCIN
2 3VIN
READ/WRITE
Read Only
Read Only
Read Only
Reserved
Read Only
Read Only
DESCRIPTION
A one indicates a High or Low limit has been exceeded from
CPUT2 sensor.
A one indicates a High or Low limit has been exceeded from
CPUT1 sensor.
A one indicates a High or Low limit has been exceeded from
W83L784R internal temperature sensor.
Reserved
A one indicates a High or Low limit has been exceeded.
( VCC, +5V)
A one indicates a High or Low limit has been exceeded.
(VIN2)
1 VBATIN
0 VCOIN
Read Only
Read Only
A one indicates a High or Low limit has been
exceeded.(VIN3 )
A one indicates a High or Low limit has been exceeded.
(VIN1)
- 21 -
Publication Release Date: Jan. 2005
Revision 1.1