8.2 Data Register (Port x6h)
Data Port:
Power on Default Value
Attribute:
Size:
Port x6h
00h
Read/write
8 bits
7 6 5 4 32 1 0
W83781D
PRELIMINARY
Data
Bit 7-0: Data to be read from or to be written to RAM and Register.
8.3 Configuration Register - Index 40h (Bank 0)
Register Location:
Power on Default Value
Attribute:
Size:
40h
00000001 binary
Read/write
8 bits
7 6 5 4 32 1 0
START
EN_SMI#
EN_IRQ
INT_CLEAR
RST_OUT#
IRQPOL
BEEP/GPO#
INITIALIZATION
Bit 7:The logical 1 restores power on default value to all registers except the Serial Bus Address
register. This bit clears itself since the power on default is zero.
Bit 6:The logical 1 in this bit drives a zero on GPO# pin.
Bit 5:IRQ polarity select. When set to 0, IRQ active high. Set to 1, IRQ active low. Default 0.
Bit 4:The logical 1 outputs at least a 20 ms active low reset signal at RST_OUT# if <7> = 1 in SMI#
Mask Register 2. This bit is cleared once the pulse has gone inactive.