English
Language : 

W963L6ABN Datasheet, PDF (13/30 Pages) Winbond – 512K WORD X 16 BIT LOW POWER PSEUDO SRAM
W963L6ABN
AC Characteristics, Continued
Power Down and Power Down Program Parameters
PARAMETER
CE2 Low Setup Time for Power Down Entry
CE2 Low Hold Time after Power Down Entry
SYM.
tCSP
tC2LP
-70
Min. Max.
10 -
70 -
-80
Min. Max.
10 -
80 -
UNIT NOTES
nS
nS
CE1 High Setup Time following CE2 High after tCHS 10
-
10
-
nS
Power Down Exit
CE1 High to PE Low Setup Time
tEPS
70
-
80
-
nS *1
Note: *1: Applicable to Power Down Program
Other Timing Parameters
PARAMETER
-70
-80
SYM.
UNIT NOTES
Min. Max. Min. Max.
CE1 High to OE Invalid Time for Standby Entry tCHOX 10
-
10
-
nS
CE1 High to WE Invalid Time for Standby Entry tCHWX 10
-
10
-
nS *1
CE2 Low Hold Time after Power-up
tC2LH 50
-
50
-
µS *2
CE2 High Hold Time after Power-up
tC2HL 50
-
50
-
µS *3
CE1 High Hold Time following CE2 High after
Power-up
Input Transition Time
tCHH 350 - 350 -
µS *2
tT
1 25 1 25 nS *4
Notes:
*1: Some data might be written into any address location if tCHWX(min.) is not satisfied.
*2: Must satisfy tCHH(min.) after tC2LH(min.).
*3: Requires Power Down mode entry and exit after tC2HL.
*4: The Input Transition Time (tT) at AC testing is 5 nS as shown in below. If actual tT is longer than 5 nS, it may violate
AC specified of some timing parameters.
AC Test Conditions
SYMBOL
DESCRIPTION
VIH Input High Level
VIL Input Low Level
VREF
TT
Input Timing Measurement Level
Input Transition Time
TEST SETUP
VDD = 2.7V to 3.3V
VDD = 2.3V to 2.7V
VDD = 2.7V to 3.3V
VDD = 2.3V to 2.7V
VDD = 2.7V to 3.3V
VDD = 2.3V to 2.7V
Between VIL and VIH
VALUE
2.3
2.0
0.4
0.4
1.3
1.1
5
UNIT NOTE
V
V
V
nS
- 13 -
Publication Release Date: March 11, 2003
Revision A1