Electrical Specifications (Cont.)
Specifications apply over all line and load conditions, unless otherwise noted; boldface specifications apply over the temperature range of -40°C ≤ TCASE
≤100°C (T-Grade); all other specifications are at TCASE = 25ºC unless otherwise noted.
­Attribute
Symbol
Conditions / Notes
Min
Typ
Max
Unit
Powertrain Supervisory Limits Specification – Forward Direction Operation (High Voltage Side to Low Voltage Side)
• These supervisory limits are set in the internal controller and can be reconfigured or disabled through PMBus™.
• When disabled, the powertrain protections presented in the previous table will intervene during fault events.
HI Side Overvoltage Lockout
Threshold
HI Side Overvoltage Recovery
Threshold
HI Side Overvoltage Lockout
Hysteresis
HI Side Overvoltage Lockout
Response Time
HI Side Undervoltage Lockout
Threshold
HI Side Undervoltage Recovery
Threshold
HI Side Undervoltage Lockout
Hysteresis
HI Side Undervoltage Lockout
Response Time
VHI_OVLO+
VHI_OVLO-
VHI_OVLO_HYST
tHI_OVLO
VHI_UVLO-
VHI_UVLO+
VHI_UVLO_HYST
tHI_UVLO
420
434.5
450
V
405
424
440
V
10.5
V
100
µs
200
226
250
V
225
244
259
V
15
V
100
µs
HI Side Undervoltage Startup Delay
tHI_UVLO+_DELAY
From VHI_DC = VHI_UVLO+ to powertrain active, (i.e One
time startup delay from application of VHI_DC to VLO_DC)
20
ms
LO Side Overcurrent Trip Threshold
ILO_OUT_OCP
159
168
177
A
LO Side Overcurrent
Response Time Constant
tLO_OUT_OCP Effective internal RC filter
2
ms
Overtemperature Shutdown
Threshold
tOTP+
Internal
125
°C
Overtemperature Recovery
Threshold
tOTP–
Internal
105
110
115
°C
Undertemperature Shutdown
Threshold (Internal)
C-Grade
tUTP
T-Grade
-25
°C
-45
Undertemperature Restart Time
tUTP_RESTART
Startup into a persistent fault condition. Non-latching
fault detection given VHI_DC > VHI_UVLO+
3
s
BCM® in a VIA Package
Page 8 of 42
Rev 1.5
10/2016
vicorpower.com
800 927.9474