English
Language : 

BCM4414XD1E13A2YZZ Datasheet, PDF (5/42 Pages) Vicor Corporation – Isolated Fixed-Ratio DC-DC Converter
BCM4414xD1E13A2yzz
Absolute Maximum Ratings
The absolute maximum ratings below are stress ratings only. Operation at or beyond these maximum ratings can cause permanent damage to the device.
Parameter
Comments
Min
Max
Unit
+HI to –HI
-1
480
V
HI_DC or LO_DC slew rate
N/A
V/µs
+LO to –LO
-1
15
V
EXT BIAS to SGND
-0.3
10
V
0.15
A
SCL to SGND
-0.3
5.5
V
SDA to SGND
-0.3
5.5
V
ADDR to SGND
-0.3
3.6
V
(High voltage side to case)
2121
VDC
Isolation Voltage /
Dielectric Withstand
Basic Insulation (High voltage side to low voltage side) [1]
2121
VDC
(Low voltage side to case)
N/A
VDC
[1] The absolute maximum rating listed above for the Dielectric Withstand (high voltage side to the low voltage side) refers to the VIA package. The internal
safety approved isolating component (ChiP) provides reinforced insulation (4242V) from the high voltage side to the low voltage side. However, the VIA
package itself can only be tested at a basic insulation value (2121V).
BCM® in a VIA Package
Page 5 of 42
Rev 1.5
10/2016
vicorpower.com
800 927.9474